IPS-PFC500-36 Hot selling slim thin high PFC switching power supply 12v 24V 36V 500W with UL KC FCC CE
MODEL:IPS-PFC500-36 switching power supply 36v 500w SPECIFICATION: ① AC input: Single-phase 110/220V±15% 50/60hz ② DC output: 0~36VDC, 13.8A ③ Power: 500W ④ Dimension:179*112*43MM ⑤Package size: 45.5(L)*23.3(W)*37.5H)CM ⑥NW: 0.53KG, GW: 0.54KG

I. INPUT CHARACTERISTICS

Model

IPS-PFC500-36

input voltage

95-264Vac

Input frequency

50/60HZ

Input current

5.42A

efficiency

≥93%

Cooling method

Air Cooling

working temperature

-25-50℃

No load power consumption

<2W

Surge current

≤25A

Start time

≤3.5S

Hold time

≥10MS

Input structure

Three wire inputs, namely: live wire, neutral wire, and ground wire

Linear adjustment rate

Within the input voltage range, the online adjustment rate is < ± 1%

Input protection

When the input current is greater than the rated current of the fuse, the fuse will blow

High voltage testing

Input to shell 1600Vac 5mA 3sec

Insulation impedance

Primary to secondary 500Vdc 100MΩ

 

II. OUTPUT CHARACTERISTIC

2-1. Output voltage and current

Output voltage

Error Range

Output Current

36VDC

±0.1%

MIN

MAX

0A

13.8A

12V (optional/optional)

±0.1%

0A

2A

 

2-1 Load Regulation

Under the conditions of AC input voltage, output load current, and ripple noise changes, the rate of change of output voltage should be within ± 0.5% of the rated output voltage.

 

2-3. Ripples and noise

Output voltage

Ripple and noise

36VDC

260mV (MAX)

Explanation: The ripple test is conducted at a frequency range of 20MHz and room temperature of 25 ℃ on the oscilloscope, and a 10uF/50V electrolytic capacitor and a 0.1uF/50V ceramic capacitor are connected in parallel at the output end

 

2-4. Overvoltage protection

 

When the output voltage is higher than 10% of the rated output voltage, the machine will enter a protective state and can resume normal operation after returning to the rated output voltage

 

2-5. Overcurrent protection

 

When the working current of the machine is greater than 14A, the power supply will operate in constant current mode.

 

2-6. Short circuit protection

 

When the machine is operating normally (with normal input voltage and load), a short circuit at the output end will not cause damage or safety issues to the machine itself, and the machine can resume normal operation after the short circuit is cancelled

 

2-7. Leakage current

 

When the input voltage is 264Vac 50Hz, the leakage current should be ≤ 3.5mA

 

2-8. Indicator lights

 

2-9. Static electricity requirements

 

1.) This power adapter

 

Must comply with EN50082-1:1997 standard

 

2. The basic standards are as follows:

 

a. EN61000-4-3

 

b. EN61000-4-4

 

c. EN61000-4-5

 

 

III. ENVIRONMENTAL CHARACTERISTICS

 

3-1 Temperature

 

1. Working temperature: -10 ℃ to+70 ℃ (with rated operation)

 

2. Storage temperature: -20 ℃ to+85 ℃

 

3.) Storage height: 40000 feet

 

3-2. Humidity

 

1. Working relative humidity: 10% to 90% (non condensing)

 

2. Storage relative humidity: 5% to 95% (non condensing)

 

3-3. Temperature Derating Curve

 

3-4. Altitude

image.png 

 

 

IV. EMI/EMC STANDARDS

 

Complies with GB9254-1998 GB17625.1-2003 EN55022

 

V. SAFETY STANDARDS

 

Compliant with CE 3C UL

 

VI. RELIABILITY

 

Mean time between failures: Under normal input voltage, room temperature of 25 ℃, and full load operation, the MBTF should be ≥ 50000 hours

 

VIII. MECHANICAL CHARACTERISTICS

 

7-1. Appearance dimensions

 

Length: 175mm

Width: 110mm

Height: 40mm

 

 

 

 

IX. REFERENCE PICTURE