Product Categories

IPS-MDR-100-12 DIN Rail MDR-100 100W Input 100-240V AC Output DC 48V 12V 7.5A 24V 4A Industrial Switching Power Supply DC power supply MDR
MODEL:IPS-MDR-100-12 Rail Power Supply 12v 100w SPECIFICATION: ① AC input: Single-phase 100-240VAC 50/60hz ② DC output: 12VDC,7.5A ③ Power: 100W ④ Dimension: 40*90*100MM ⑤ NW: 0.42KG

Features:

1. International universal voltage input range: 85-264VAC/120-370VDC

2. Protection type: short circuit/over power

3. Natural air cooling

4. Up to 88% work efficiency

5. DC OK relay detection function

6. Standby power consumption as low as 0.3W

7. 100% full load burn-in test

8. 2-year warranty

 

1.Electrical specifications

Module

MDR- 100-5

MDR- 100- 12

MDR- 100- 15

MDR- 100-24

MDR- 100-48

 

 

 

 

 

Output characteristic

DC output

5V

12V

15V

24V

48V

Rated current

8A

7.5A

6.5A

4A

2A

Current range

0-8A

0-7.5A

0-6.5A

0-4A

0-2A

Rated power

80W

90W

97.5W

96W

96W

Ripple&Noise (maximum)

100mVp-p

120mVp-p

150mVp-p

200mVp-p

250mVp-p

Voltage adjustment range

4.5-5.5V

10.2-13.8V

13.5-18V

21.6-28.8V

43.2-52.8V

Voltage accuracy

± 2%

±1%

±1%

±1%

± 1%

Linear adjustment rate

± 0.5%

±0.5%

±0.5%

±0.5%

± 0.5%

Load adjustment rate

± 2%

±1%

±0.5%

±0.5%

± 0.5%

Load adjustment rate

500mS,30mS/230VAC;1000mS,30mS/ 1 15VAC  (Full load)

Hold time

30mS/230VAC;10mS/ 1 15VAC  (Full load)

 

 

 

Input characteristics

Input voltage

85-264VAC        120-375V DC

Input frequency

47-63HZ

Efficiency

78%

86%

87%

88%

90%

Input current

1.9A/ 1 15VAC     1 。2A/230VAC

power factor

0.65/ 1 15VAC   0.5/230VAC

Surge current

55A/230VAC

Surge current

<1.0mA/240VAC

Function

DC OK signal

Relay contact current (maximum): 30V/1A Resistive load

 

 

Protective characteristics

Over load protection

110% -180% of rated power

Protection mode: Hiccup protection, automatically restored after abnormal conditions are removed

Over voltage protection

5.7-6.8V

14-17V

18-22V

28-33V

55-65V

Protection mode: Hiccup protection, automatically restored after abnormal conditions are removed

Short circuit protection

Short circuit between positive and negative poles at the output end

Protection mode: Hiccup protection, automatically restored after abnormal conditions are removed

 

Environmental

Working temperature

-30℃~70℃(Refer to the derating curve)

Working humidity

20~90%RH No condensation

Storage temperature/humidity

-40℃~85℃ 10~95%RH,No condensation

Anti vibration

10~500HZ, 5G 10 minutes/cycle, X, Y, Z each 60 minutes

 

 

Safety and electromagnetic compatibility

Withstand voltage

Input to output: 1.5KVAC

Insulation impedance

Input to output: 100Ohms/500V DC/25 ℃/70% RH

Electromagnetic compatibility emission

Compliant with EN55032 class A

Electromagnetic compatibility immunity

Compliant with EN61000-4-2

Safety regulations

Complies with GB4943

Others

Product size

40*90*100(L*W*H)

Package(KG)

0. 42kg/pcs

Notes

1. All parameters, unless otherwise specified, are measured at 230VAC voltage input, rated load, and 25 ℃ conditions.

2. Ripple and noise voltage are applied at the end of a 12 inch twisted pair oscilloscope with a bandwidth of 20MHz and an additional 0.1 μ And 47 μ The capacitance is measured at a bandwidth of 20MHZ. 3. Accuracy: including setting error, linear adjustment rate, and load adjustment rate.

4. In the case of low input voltage, it is necessary to derate the output. Please refer to the static characteristic curve for details.

5. The startup time is measured during cold start, and frequent switching on and off may increase the startup time.


WhatsApp
Wechat
Contact Us
Your Name:
Your Email:
Your Message:
This website uses cookies to enhance user experience and to analyze performance and traffic on our website.
We also share information about your use of our site with our social media, advertising and analytics partners.
Do Not Sell My Personal Information
Accept Cookies