INTRODUCTION
In many important occasions, the reliability of the load of electricity consumption is very important. In order to improve the reliability of the load, the general power supply system adopts dual power supply, such as dual main power, one main power and UPS. However, the more reliable method is to use dual UPS power supply, such as many IDC computer rooms, bank business outlets, telecommunications, mobile, and many important loads in the power systems. For dual power supply, how to safely, quickly and effectively switch directly affect load reliability, especially many equipment acceptable outage time is extremely demanding, such as: outage time cannot exceed 10ms, in the face of this requirement, ordinary ATS mechanical contacts is not bear, and high speed static no contact STS and rapid power detection can quickly, safely and effectively realize double power switch.
KEY SPECIFICATIONS
Model | Input Voltage | Input Frequency | Output Current | Switching types | Display type |
IPS-STS45S | 190~260VAC | 50/60HZ | 45A | Dual | LED |
ELECTRICAL CHARACTERISTICS
Brand | IDEALPLUSING | |
Model | IPS-STS45S | |
Switching types | Single | |
Display type | LED | |
Switch time | Priority switching | ≤4m s |
Input characteristics | Rated voltage | 220VAC |
Input voltage range | 190~260VAC | |
rated frequency | 50/60HZ | |
power factor | 1 | |
Auto convert threshold voltage | ≤ 190Vac ± 5Vac or ≥260Vac ± 5Vac | |
Auto convert threshold frequency | ≤45Hz±0.2Hz or ≥65Hz±0.2Hz | |
Over-limit protection shutdown threshold voltage | 160Vac or 265Vac, return ± 5V | |
Over-limit protection shutdown threshold frequency | 45Hz or 65Hz, with differential ± 0.2Hz | |
overload capacity | Load current is 110%, operating continuously Load current> 110%, immediately shut-off; | |
Environment | insulation strength | 2KVAC,1min |
Noise (1m) | ≤55dB | |
operating ambient temperature | -25~50℃ | |
Transport and storage temperature | -40~70℃ | |
humidity | 0~90%, with no condensation | |
levels of protection | IP20 | |
height (m) | ≤3000 2000~3000m Output reduction of 2% per 100m increase | |
defencive function | Input under voltage, over voltage protection, output overload protection, over temperature protection, short circuit protection |
DETAILS IMAGES
MODEL LIST
Model | Input Voltage | Output Current |
Relay version STS | ||
IPS-DQ16J | 190~260VAC | 16A |
IPS-DQ25J | 190~260VAC | 25A |
IPS-DQ32J | 190~260VAC | 32A |
Thyristor board STS | ||
IPS-STS16S | 190~260VAC | 16A |
IPS-STS25S | 190~260VAC | 25A |
IPS-STS32S | 190~260VAC | 32A |
IPS-STS40S | 190~260VAC | 40A |
IPS-STS45S | 190~260VAC | 45A |
IPS-STS16D | 190~260VAC | 16A |
IPS-STS25D | 190~260VAC | 25A |
IPS-STS32D | 190~260VAC | 32A |
IPS-STS40D | 190~260VAC | 40A |
IPS-STS45D | 190~260VAC | 45A |
IPS-STS063SM | 190~260VAC | 63A |
IPS-STS080SM | 190~260VAC | 80A |
IPS-STS100SM | 190~260VAC | 100A |
IPS-STS125SM | 190~260VAC | 125A |
IPS-STS063DM | 190~260VAC | 63A |
IPS-STS080DM | 190~260VAC | 80A |
IPS-STS100DM | 190~260VAC | 100A |
IPS-STS125DM | 190~260VAC | 125A |
IPS-STS063SMT | 323~437VAC | 63A |