Features:
1. International universal voltage input range: 85-264VAC/120-370VDC
2. Protection type: Short circuit ,Over current ,Over voltage.
3. Natural air cooling
4. Up to 88% work efficiency
5. Standby power consumption as low as 0.3W
6. 100% full load burn-in test
7. 2-year warranty
Electrical specifications
MODEL | HDR-15-5 | HDR-15-12 | HDR-15-15 | HDR-15-24 | HDR-15-48 | |||
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 48V | ||
RATED CURRENT | 2.4A | 1.25A | 1A | 0.63A | 0.32A | |||
CURRENT RANGE | 0-2.4A | 0-1.25A | 0~1A | 0-0.63A | 0~0.32A | |||
RATED POWER | 12W | 15W | 15W | 15.2W | 15.4W | |||
RIPPLE&NOISE (max)Note.2 | 80mVp-p | 120mNp-P | 120mVp-p | 150mVpF | 240mVp-P | |||
VOLTAGE ADJ.RANGE | 4.5-5.5V | 10.8~13.8V | 13.5~18V | 21.6-29V | 43.2~55.2V | |||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
SETUP,RISE TIME | 2000ms,80ms/230VAC 2000ms,80ms/115VAC at full load | |||||||
HOLD UP TIME (Typ. | 30ms/230VAC 12ms/115VAC at full load | |||||||
INPUT | VOLTAGE RANGE | 85-284VAC (277VAC operational )120~370VDC(390VDC operational ) | ||||||
FREQUENCY RANGE | 47~63Hz | |||||||
EFFICIENCY (Typ. | 80% | 85% | 85.5% | 86% | 87% | |||
AC CURRENT (Typ. | 0.5A/115VAC 0.25N230VAC | |||||||
INRUSH CURRENT (Typ. | COLD START 25A/115VAC 45A/230VAC | |||||||
PROTECTION | OVERLOAD Note.4 | 110~145%rated output power | ||||||
Protection type:Constant current limiting,recovers automatically after fault condition is remove | ||||||||
OVER VOLTAGE | 5.75-6.75V | 142-16.2V | 18.8-22.5V | 30-36V | 56.5~64.8V | |||
Protection type:Shut off o/p voltage.clamping by zener diode | ||||||||
ENWRONMENT | WORKING TEMP. | -30~+70℃(Refer to'Derating Curve’) | ||||||
WORKING HUMIDITY | 20-90%RH non-condensing | |||||||
STORAGE TEMP,HUMIDITY | 40-+85℃,10-95%RH non-condensing | |||||||
TEMP.COEFFICIENT | ±0.03%/C (D-50℃)RH non-condensing | |||||||
VIBRATION | 10~500Hz,2G 10min/1cycle,period for 60min.each along X,Y,Z axes;Mounting:Compliance to IEC60068-2-6 | |||||||
OPERATING ALTITUDE | 2000 meters | |||||||
OVER VOLTAGE CATEGORY | Ⅲ;According to EN61558,EN50178,EN60664-1,EN62477-1;altitude up to 2000 meters | |||||||
SAFETY& EMC (Note 5) | SAFETY STANDARDS | UL60950-1,UL508,TUV EN61558-2-16,IEC60950-1,EAC TP TC 004,BSMI CNS14336-1 approved;Design refer to TUV EN60950-1 | ||||||
WITHSTAND VOLTAGE | UP-O/P:4KVAC | |||||||
ISOLATION RESISTANCE | VP-O/P:100M Ohms 1500VDC125C170%RH | |||||||
EMC EMISSION | Parameter | Standard | Test Level /Note | |||||
Conducted | EN55032(CISPR32),CNS13438 | Class B | ||||||
Radiated | EN55032(CISPR32).CNS13438 | Class B | ||||||
Harmonic Current | EN61000-3-2 | Class A | ||||||
Voltage Flicker | EN61000-3-3 | |||||||
EMCIMMUNITY | EN55024,EN55035,EN61000-6-2,EN61204-3 | |||||||
Parameter | Standard | Test Level /Note | ||||||
ESD | EN61000-4-2 | Level 3,8KV air;Level 2,4KV contact,criteria A | ||||||
Radiated Susceptibility | EN61000-4-3 | Level 3,criteria A | ||||||
EFT/Burest | EN61000-4-4 | Level 3,criteria A | ||||||
Surge | EN61000-4-5 | Level 4.2KVIL-N,criteria A | ||||||
Conducted | EN61000-4-6 | Level 3,criteria A | ||||||
Magnetic Field | EN61000-4-8 | Level 4.criteria A | ||||||
Voltage Dips and interruptions | EN61000-4-11 | >95%dip 0.5 periods,30%dip 25 periods >95%interruptions 250 periods | ||||||
OTHERS | MTBF | 1166K hrs min,MLHDBK-217F(25℃) | ||||||
DINENSION | 17.5*90*54.5mm (W*H*D) | |||||||
PACKING | 78g:160pcs/13.5Kg/1.19CUFT |