Features:
1. International universal voltage input range: 85-264VAC/120-370VDC
2. Protection type: Short circuit ,Over current ,Over voltage.
3. Natural air cooling
4. Up to 88% work efficiency
5. Standby power consumption as low as 0.3W
6. 100% full load burn-in test
7. 2-year warranty
Electrical specifications
MODEL | HDR-60-5 | HDR-60-12 | HDR-60-15 | HDR-60-24 | HDR-60-48 | |||
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 48V | ||
RATED CURRENT | 6.5A | 4.5A | 4A | 25A | 1.25A | |||
CURRENT RANGE | 0-6.5A | 0-4.5A | 0-4A | 0~2.5A | 0-1.25A | |||
RATED POWER | 32.5W | 54W | 60W | 60W | 60W | |||
RIPPLE &NOISE(max)Note2 | 80mVp-p | 120mVp-P | 120mNp-P | 150mVp-p | 240mVp-P | |||
VOLTAGE ADJ.RANGE | 5.0~5.5V | 10.8~13.8V | 13.5~18V | 21.6-29V | 432-55.2V | |||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
UNE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
SETUP,RISE TIME | 500ms,50ms/230VAC 500ms,50ms/115VAC at ful load | |||||||
HOLD UPTME(Typ.) | 30ms/230VAC 12ms/115VAC at full load | |||||||
INPUT | VOLTAGE RANGE | 85-264VAC(277VAC operational ) 120-370VDC(390VDC operational | ||||||
FREQUENCY RANGE | 47~63Hz | |||||||
EFFICIENCY (Typ.) | 85% | 88% | 89% | 90% | 91% | |||
AC CURRENT (Typ.) | 12A/115VAC 0.8A/230VAC | |||||||
INRUSH CURRENT (Typ.) | COLD START 30N/115VAC 60A/230VAC | |||||||
PROTECTON | OVERLOAD | 105-160% rated output power | ||||||
Hiccup mode when output voltage <50%,recovers automatically after fault condition is removed Constant current limiting within 50%-100%rated output voltage,recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE | 5.75~6.75V | 14.2~16.2V | 18.8~22.5V | 30-36V | 56.5~648V | |||
Protection type:Shut down o/p voltage,re-power on to recover | ||||||||
BWROMMENT | WORKING TEMP | -30~+70℃(Refer to 'Derating Curve" | ||||||
WORKING HUMIDITY | 20~90%RH non-condensing | |||||||
STORAGE TEMP,HUMIDITY | 40~+85℃,10~96%RH non-condensation | |||||||
TEMP.COEFFICIENT | ±0.03%/C(0~50℃)RH non-condensing | |||||||
VIBRATION | 10~500Hz,2G 10min/cycle,period for 60min.each along X,Y,Z axes;Mounting Compliance to IEC60068-2-6 | |||||||
OPERATING ALTITUDE | 2000 meters | |||||||
OVER VOLTAGE CATEGORY | Ⅲ;According to EN61558,EN50178,EN60664-1,EN62477-1;altitude up to 2000 meters | |||||||
SAFETY& EMC Note 4) | SAFETY STANDARDS | UL62368-1,UL508,TUV BS EN/EN61558-2-16.BS EN/EN61558-1,IEC62368-1,EAC TP TC 004,BSMI CNS14336-1, IS13252(Part1)IIEC60950-1 approved;Design refer to BS EN/EN62368-1 | ||||||
WITHSTAND VOLTAGE | UP-OP4KVAC | |||||||
ISOLATION RESISTANCE | UP-O/P:100M Ohms 1500VDC125 C170%RH | |||||||
EMC EMISSION | Parameter | Standard | Test Level/Note | |||||
Conducted | BS EN/EN55032(CISPR32).CNS13438 | Class B | ||||||
Radiated | BS ENEN55032(CISPR32),CNS13438 | Class B | ||||||
Harmonic Current | BS EN/EN61000-3-2 | Class A | ||||||
Voltage Flicker | BS EN/EN61000-3-3 | |||||||
EMC IMMUNITY | BS EN/EN55024,BS EN/EN55035,BS EN/EN61000-6-2,BS EN/EN61204-3 | |||||||
Parameter | Standard | Test Level /Note | ||||||
ESD | BS EN/EN61000-4-2 | Level 3,8KV air,Level 2,4KV contact,criteria A | ||||||
Radiated Susceptibility | BS EN/EN61000-4-3 | Level 3,criteria A | ||||||
EFT/Burest | BS EN/EN61000-4-4 | Level 3,criteria A | ||||||
Surge | BS EN/EN61000-4-5 | Level4,2KV/L-N,criteria A | ||||||
Conducted | BS EN/EN61000-4-6 | Level 3,criteria A | ||||||
Magnetic Field | BS EN/EN61000-4-8 | Level4,criteria A | ||||||
Voltage Dips and interruptions | BS EN/EN61000-4-11 | >95%dip0.5periods,30%dip 25 periods >95%interruptions 250 periods | ||||||
OTHERS | MTBF | 927.6K hrs min.MILHDBK-217F(25℃) | ||||||
DMENSION | 52.5*90*54.5mm (WH'D) | |||||||
PACKING | 190g,60pcs'124Kg10.97CUFT |