IPS-LA33-800K-HV 800KVA Shore Power Supply System Support Port Sustainable Development Significantly Reduce Noise Pollution
①Model: IPS-LA33-800K-HV ②AC INPUT: 3-phase 3-wire / 3-phase 4-wire 10KVAC±15% 45~65HZ or Customize ③AC OUTPUT: 3-phase 3(4)-wire 440/480VAC (0-500V adjustable) 50/60HZ (45-65HZ adjustable) ④Maximum equipment power: 920KVA ; Rated equipment power: 800KVA ⑤Application: High-voltage power supply areas, large ship repair yards, remote port power supply (or customized for different areas) ⑥Adjusting method: 7-inch LCD touchscreen, switchable between Chinese and English, integrated display and control, and clear display of operating data ⑦Power factor ≥0.95, THD ≤3%, insulation resistance ≥20MΩ (DC 500V), dielectric strength 1800VAC/5mA/1min ⑧Protection features include overvoltage protection, overcurrent protection, short circuit protection, inverter overheating protection, and load capacity alarm.
Datasheet: Download

Machine model

LA33-300K

LA33-450K

LA33-500K

LA33-600K

LA33-800K

Control method

IGBT/PWM pulse width modulation method

 

Input

Voltage

380±10%

Frequency

45~~65Hz

 

 

 

 

 

Output

Voltage

440V/480V, 3-phase 3(4)-wire system, voltage (0-500V) arbitrarily adjustable

Voltage regulation rate

≤1%

Frequency

50Hz/60Hz selectable, 45Hz-65Hz continuously adjustable

Frequency stability

Fixed frequency ≤±0.01%, variable frequency ≤±0.1%

Load regulation rate

1% (100% purely resistive load)

Current

400A

600A

680A

800A

1050A

Waveform voltage

Sine wave, total harmonic distortion (THD) ≤3%

Efficiency

≥94% (100% load)

Display

7-inch LCD touchscreen display showing voltage, current, frequency, power, and power factor

Cooling method

Inverter: heat pipe cooling; Transformer: forced fan cooling

 

Output protection

The output power supply has comprehensive protection functions against overvoltage, overcurrent, short circuit, and inverter overheating.  Considering the power load control of different vessels, an alarm signal is issued when the output load capacity reaches a certain value to facilitate power load control.

 

 

environment

Insulation resistance

DC ≥500V 20 MΩ

Dielectric strength

AC 1800V 5mA/1 minute

Operating temperature

-10°C-50°C

Relative humidity

0-90% (non-condensing)

Altitude

≤1500m

Indoor protection rating

IP22

Outdoor protection rating

IP54


Machine model

LA33-300K

LA33-450K

LA33-500K

LA33-600K

LA33-800K

Control method

IGBT/PWM pulse width modulation method

 

Input

Voltage

10KV±15%

Frequency

45~~65Hz

 

 

 

 

 

Output

Voltage

440V/480V, 3-phase 3(4)-wire system, voltage (0-500V) arbitrarily adjustable

Voltage regulation rate

≤1%

Frequency

50Hz/60Hz selectable, 45Hz-65Hz continuously adjustable

Frequency stability

Fixed frequency ≤±0.01%, variable frequency ≤±0.1%

Load regulation rate

1% (100% purely resistive load)

Current

400A

600A

680A

800A

1050A

Waveform voltage

Sine wave, total harmonic distortion (THD) ≤3%

Efficiency

≥94% (100% load)

Display

7-inch LCD touchscreen display showing voltage, current, frequency, power, and power factor

Cooling method

Inverter: heat pipe cooling; Transformer: forced fan cooling

 

Output protection

The output power supply has comprehensive protection functions against overvoltage, overcurrent, short circuit, and inverter overheating.  Considering the power load control of different vessels, an alarm signal is issued when the output load capacity reaches a certain value to facilitate power load control.

 

 

environment

Insulation resistance

DC ≥500V 20 MΩ

Dielectric strength

AC 1800V 5mA/1 minute

Operating temperature

-10°C-50°C

Relative humidity

0-90% (non-condensing)

Altitude

≤1500m

Indoor protection rating

IP22

Outdoor protection rating

IP54


Machine model

LA33-300K

LA33-800K

LA33-1000K

LA33-2000K

LA33-3000K

Control method

IGBT/PWM pulse width modulation method

 

Input

Voltage

10KV±10%

Frequency

45~~65Hz

 

 

 

 

 

Output

Voltage

440V, voltage (0-500V) can be set arbitrarily.

Voltage regulation rate

≤1%

Frequency

50Hz/60Hz selectable, 45Hz-65Hz continuously adjustable

Frequency stability

Fixed frequency ≤±0.01%, variable frequency ≤±0.1%

Load regulation rate

≤1% (100% purely resistive load)

Current

400A

1050A

1312A

2624A

3936A

Waveform voltage

Sine wave, total harmonic distortion (THD) ≤3%

Efficiency

≥90% (100% load)

Display

7-inch LCD touchscreen display showing voltage, current, frequency, power, and power factor

Cooling method

Inverter: heat pipe cooling; Transformer: forced fan cooling

 

Output protection

The output power supply has comprehensive protection functions against overvoltage, overcurrent, short circuit, and inverter overheating.  Considering the power load control of different vessels, an alarm signal is issued when the output load capacity reaches a certain value to facilitate power load control.

 

 

environment

Insulation resistance

DC ≥500V 20 MΩ

Dielectric strength

AC 1800V 5mA/1 minute

Operating temperature

-10°C-50°C

Relative humidity

0-90% (non-condensing)

Altitude

≤1500m

Outdoor protection rating

IP65



Machine model

LA33

1000K

2000K

3000K

4000K

5000K

Control method

IGBT/PWM pulse width modulation method

 

Input

Voltage

10KV±10%

Frequency

50HZ±10%

 

 

 

 

 

Output

Voltage

6.6KV, voltage (0-7KV) can be set arbitrarily.

Voltage regulation rate

≤1%

Frequency

50Hz/60Hz selectable, 45Hz-65Hz continuously adjustable

Frequency stability

Fixed frequency ≤±0.01%, variable frequency ≤±0.1%

Load regulation rate

≤1% (100% purely resistive load)

Current

87A

175A

262A

350A

432A

Waveform voltage

Sine wave, total harmonic distortion (THD) ≤3%

Efficiency

≥90% (100% load)

Display

7-inch LCD touchscreen display showing voltage, current, frequency, power, and power factor

Cooling method

Inverter: heat pipe cooling; Transformer: forced fan cooling

 

Output protection

The output power supply has comprehensive protection functions against overvoltage, overcurrent, short circuit, and inverter overheating.  Considering the power load control of different vessels, an alarm signal is issued when the output load capacity reaches a certain value to facilitate power load control.

 

 

environment

Insulation resistance

DC ≥500V 20 MΩ

Dielectric strength

AC 1800V 5mA/1 minute

Operating temperature

-10°C-50°C

Relative humidity

0-90% (non-condensing)

Altitude

≤1500m

Outdoor protection rating

IP65


WhatsApp
Wechat
Contact Us
Your Name:
Your Email:
Your Message:
This website uses cookies to enhance user experience and to analyze performance and traffic on our website.
We also share information about your use of our site with our social media, advertising and analytics partners.
Do Not Sell My Personal Information
Accept Cookies