Product Categories

IPS-ATDP5004 2000W Adjustable DC Laboratory Supply Predictive Maintenance System Field Service Support
① AC INPUT: Single phase 220VAC±10% 50/60HZ ② DC OUTPUT: 0~500VDC, 0.1~4A ③ Max power: 2000W ④ Machine size: L450W320H145(MM) ⑤ NW: 10.0KG, GW: 11.5KG ⑥ Voltage indicator: Including ⑦ Current indicator: Including ⑧ Communication: RS485*1 ⑨ Cooling Method: Air cooling ⑩ Protection: lower voltage, over voltage, over current, short circuit, overheating Wechat Number/Whatsapp ID: +86-18928830209 Email: info@idealplusing.com Office telephone number:+86-20-89282095
Datasheet: Download


AC Input

Single-phase 220V ±10% or three-phase 380V ±10%

Frequency: 50Hz/60Hz

Model

IPS-ATDP5004

Output Voltage

0~500VDC

Output Current

0.1~4A

Output Power

2000W

Power Supply Stability

≦ 0.2%+10mV

Load Stability

≦ 0.2%+30mV

Ripple

≤ 0.5%+10mV( rms)

 

Voltage Value Display

4-digit display meter  Accuracy: ±0.3%FS + 3 digits (10%-100% of rated value)

Display format: 0.000V-9.999V; 0.00V-99.99V; 0.0V-999.9V

 

Current Value Display

4-digit display Accuracy: ±0.3% FS + 3 digits (10%-100% of rated value)

Display format: 0.000A-9.999A; 0.00A-99.99A; 0.0A-999.9A

Menu Display

64 x 128 dot matrix LCD display

Output Overvoltage Protection

The menu allows you to set O.V.P. (Over-Voltage Protection) parameters; the protection value can be set

arbitrarily, and the output will be shut off after protection is triggered.

Output Overcurrent

Protection

The menu allows you to set O.I.P. protection; the protection value can be set arbitrarily, and the output will be

shut off after protection is triggered.

Over-Temperature Protection

Built-in OTP (Over-Temperature Protection) with a protection value of 85℃ ± 5% (heatsink temperature); output

is shut off after protection is triggered.

Voltage Setting

Menu settings, input via keyboard or encoder knob.

Current Setting

Menu settings, input via keyboard or encoder knob.

Control Interface

Standard analog signal output, RS-485 control interface.

Output Polarity

The positive (+) and negative (-) outputs can be grounded arbitrarily.

Cooling Method

Forced air cooling

Operating Environment

Designed for indoor use; temperature: 0℃ to 40℃ ; humidity: 10% to 85% RH

Storage Environment

Temperature: -20℃ ~ 70℃ ; Humidity: 10% ~ 90% RH

Note: All values are typical values; therefore, these values may be exceeded under different load conditions or other circumstances. Accuracy is measured with voltage sensing at the load terminal.  Due to temperature variations and component aging, the actual values may deviate from the rated values.


Serial Number

Model

Input

Voltage (V)

Output

Voltage (V)

Output

Current (A)

Power (W)

Dimensions/MM

(H*W*L)

Net Weight (KG)

Gross Weight

(KG)

1

IPS-ATDP8250

220VAC

8VDC

250A

2000W

145*320*450

11.0

12.5

2

IPS-ATDP10200

220VAC

10VDC

200A

2000W

145*320*450

11.0

12.5

3

IPS-ATDP16125

220VAC

16VDC

125A

2000W

145*320*450

10.0

11.5

4

IPS-ATDP20100

220VAC

20VDC

100A

2000W

145*320*355

9.6

10.8

5

IPS-ATDP2580

220VAC

25VDC

80A

2000W

145*320*355

9.6

10.8

6

IPS-ATDP4050

220VAC

40VDC

50A

2000W

145*320*355

9.6

10.8

7

IPS-ATDP5040

220VAC

50VDC

40A

2000W

145*320*355

9.6

10.8

8

IPS-ATDP8025

220VAC

80VDC

25A

2000W

145*320*355

9.6

10.8

9

IPS-ATDP10020

220VAC

100VDC

20A

2000W

145*320*355

10.0

11.5

10

IPS-ATDP12516

220VAC

125VDC

16A

2000W

145*320*355

10.0

11.5

11

IPS-ATDP16012.5

220VAC

160VDC

12.5A

2000W

145*320*355

10.0

11.5

12

IPS-ATDP20010

220VAC

200VDC

10A

2000W

145*320*355

9.6

10.8

13

IPS-ATDP2508

220VAC

250VDC

8A

2000W

145*320*355

9.6

10.8

14

IPS-ATDP4005

220VAC

400VDC

5A

2000W

145*320*450

9.6

10.8

15

IPS-ATDP5004

220VAC

500VDC

4A

2000W

145*320*450

10.0

11.5

16

IPS-ATDP8002.5

220VAC

800VDC

2.5A

2000W

145*320*450

10.0

11.5

17

IPS-ATDP10002

220VAC

1000VDC

2A

2000W

145*320*450

10.0

11.5

18

IPS-ATDP15001.3

220VAC

1500VDC

1.3A

2000W

145*320*450

11.0

12.5

19

IPS-ATDP20001

220VAC

2000VDC

1A

2000W

145*320*450

11.0

12.5

              

                        Functional Device Description-Front


       image.png

image.png

Instructions

1. LCD display: Human-machine interaction interface, displaying Chinese menu;

2. Keyboard: Function keys and number keys;

3. Digital encoder: Can be used as an input substitute for the keyboard;

4. OUTPUT: This indicator light is on when there is output from the power supply;

5. "C.V" Status Indicator: Steady on indicates that the DC power supply is operating in constant voltage mode.

6. "C.C" Status Indicator: Steady on indicates that the DC power supply is operating in constant current (or current limiting) mode.

7. REMOTE Indicator: Remote control indicator, this light is on when remote control is active;

8. OV Indicator: Overvoltage protection indicator, this light is on during overvoltage conditions;

9. OI Indicator: Overcurrent protection indicator, this light is on during overcurrent conditions;

10. OT Indicator: Overtemperature protection indicator, this light is on during overtemperature conditions;

11. SHORT: Short circuit indicator, this light is on when the power supply is in a short circuit state;

12. Power Switch: Used to start and shut down


              

                        Functional Device Description-Back


             

                 

image.png

                         

image.png


WhatsApp
Wechat
Contact Us
Your Name:
Your Email:
Your Message:
This website uses cookies to enhance user experience and to analyze performance and traffic on our website.
We also share information about your use of our site with our social media, advertising and analytics partners.
Do Not Sell My Personal Information
Accept Cookies