Product Categories

IPS-ATDP32250 8000W Adjustable DC Laboratory Supply Seismometer Power for Moon Mars Rover Power Emulator
① AC INPUT: Single phase 220VAC±10% 50/60HZ ② DC OUTPUT:0~32VDC, 0.1~250A ③ Max power: 8000W ④ Machine size: L455W430H190(MM) ⑤ NW: 23.0KG, GW: 31.0KG ⑥ Voltage indicator: Including ⑦ Current indicator: Including ⑧ Communication: RS485*1 ⑨ Cooling Method: Air cooling ⑩ Protection: lower voltage, over voltage, over current, short circuit, overheating Wechat Number/Whatsapp ID: +86-18928830209 Email: info@idealplusing.com Office telephone number:+86-20-89282095
Datasheet: Download


AC Input

Single-phase 220V ±10% or three-phase 380V ±10%

Frequency: 50Hz/60Hz

Model

IPS-ATDP32250

Output Voltage

0~32VDC

Output Current

0.1~250A

Output Power

8000W

Power Supply Stability

≦ 0.2%+10mV

Load Stability

≦ 0.2%+30mV

Ripple

≤ 0.5%+10mV( rms)

 

Voltage Value Display

4-digit display meter  Accuracy: ±0.3%FS + 3 digits (10%-100% of rated value)

Display format: 0.000V-9.999V; 0.00V-99.99V; 0.0V-999.9V

 

Current Value Display

4-digit display Accuracy: ±0.3% FS + 3 digits (10%-100% of rated value)

Display format: 0.000A-9.999A; 0.00A-99.99A; 0.0A-999.9A

Menu Display

64 x 128 dot matrix LCD display

Output Overvoltage Protection

The menu allows you to set O.V.P. (Over-Voltage Protection) parameters; the protection value can be set

arbitrarily, and the output will be shut off after protection is triggered.

Output Overcurrent

Protection

The menu allows you to set O.I.P. protection; the protection value can be set arbitrarily, and the output will beshut off after protection is triggered.

Over-Temperature Protection

Built-in OTP (Over-Temperature Protection) with a protection value of 85℃ ± 5% (heatsink temperature); output is shut off after protection is triggered.

Voltage Setting

Menu settings, input via keyboard or encoder knob.

Current Setting

Menu settings, input via keyboard or encoder knob.

Control Interface

Standard analog signal output, RS-485 control interface.

Output Polarity

The positive (+) and negative (-) outputs can be grounded arbitrarily.

Cooling Method

Forced air cooling

Operating Environment

Designed for indoor use; temperature: 0℃ to 40℃ ; humidity: 10% to 85% RH

Storage Environment

Temperature: -20℃ ~ 70℃ ; Humidity: 10% ~ 90% RH

Note: All values are typical values; therefore, these values may be exceeded under different load conditions or other circumstances. Accuracy is measured with voltage sensing at the load terminal.  Due to temperature variations and component aging, the actual values may deviate from the rated values.


            

Serial Number

Model

Input

Voltage (V)

Output

Voltage (V)

Output

Current (A)

Power (W)

Dimensions/MM

(H*W*L)

Net Weight (KG)

Gross Weight

(KG)

1

IPS-ATDP16500

220VAC

16VDC

500A

8000W

190*430*455

24

32.0

2

IPS-ATDP20400

220VAC

20VDC

400A

8000W

190*430*455

24

32.0

3

IPS-ATDP25320

220VAC

25VDC

320A

8000W

190*430*455

23

31.0

4

IPS-ATDP32250

220VAC

32VDC

250A

8000W

190*430*455

23

31.0

5

IPS-ATDP40200

220VAC

40VDC

200A

8000W

190*430*455

22

30.0

6

IPS-ATDP50160

220VAC

50VDC

160A

8000W

190*430*455

22

30.0

7

IPS-ATDP64125

220VAC

64VDC

125A

8000W

190*430*455

22

30.0

8

IPS-ATDP80100

220VAC

80VDC

100A

8000W

190*430*455

22

30.0

9

IPS-ATDP10080

220VAC

100VDC

80A

8000W

190*430*455

22

30.0

10

IPS-ATDP12564

220VAC

125VDC

64A

8000W

190*430*455

22

30.0

11

IPS-ATDP16050

220VAC

160VDC

50A

8000W

190*430*455

22

30.0

12

IPS-ATDP20040

220VAC

200VDC

40A

8000W

190*430*455

22

30.0

13

IPS-ATDP25032

220VAC

250VDC

32A

8000W

190*430*455

22

30.0

14

IPS-ATDP32025

220VAC

320VDC

25A

8000W

190*430*455

22

30.0

15

IPS-ATDP40020

220VAC

400VDC

20A

8000W

190*430*455

22

30.0

16

IPS-ATDP50016

220VAC

500VDC

16A

8000W

190*430*455

22

30.0

17

IPS-ATDP60013

220VAC

600VDC

13.3A

8000W

190*430*455

22

30.0

18

IPS-ATDP80010

220VAC

800VDC

10A

8000W

190*430*455

22

30.0


                        Functional Device Description-Front


       image.png

image.png

Instructions

1. LCD display: Human-machine interaction interface, displaying Chinese menu;

2. Keyboard: Function keys and number keys;

3. Digital encoder: Can be used as an input substitute for the keyboard;

4. OUTPUT: This indicator light is on when there is output from the power supply;

5. "C.V" Status Indicator: Steady on indicates that the DC power supply is operating in constant voltage mode.

6. "C.C" Status Indicator: Steady on indicates that the DC power supply is operating in constant current (or current limiting) mode.

7. REMOTE Indicator: Remote control indicator, this light is on when remote control is active;

8. OV Indicator: Overvoltage protection indicator, this light is on during overvoltage conditions;

9. OI Indicator: Overcurrent protection indicator, this light is on during overcurrent conditions;

10. OT Indicator: Overtemperature protection indicator, this light is on during overtemperature conditions;

11. SHORT: Short circuit indicator, this light is on when the power supply is in a short circuit state;

12. Power Switch: Used to start and shut down


              

                        Functional Device Description-Back


             

                 

image.png

                         

image.png


WhatsApp
Wechat
Contact Us
Your Name:
Your Email:
Your Message:
This website uses cookies to enhance user experience and to analyze performance and traffic on our website.
We also share information about your use of our site with our social media, advertising and analytics partners.
Do Not Sell My Personal Information
Accept Cookies