Product Categories

IPS-ATDP120100 12KW Adjustable DC Laboratory Supply Heap Leach Irrigation Pump Mining Rock Crusher Motor
① AC INPUT: Three-phase 380VAC±10% 50/60HZ ② DC OUTPUT: 0~120VDC, 0.1~100A ③ Max power:12KW ④ Machine size:L264W430H650(MM) ⑤ NW: 33.0KG, GW: 43.0KG ⑥ Voltage indicator: Including ⑦ Current indicator: Including ⑧ Communication: RS485*1 ⑨ Cooling Method: Air cooling ⑩ Protection: lower voltage, over voltage, over current, short circuit, overheating Wechat Number/Whatsapp ID: +86-18928830209 Email: info@idealplusing.com Office telephone number:+86-20-89282095
Datasheet: Download


AC Input

Single-phase 220V ±10% or three-phase 380V ±10%

Frequency: 50Hz/60Hz

Model

IPS-ATDP120100

Output Voltage

0~120VDC

Output Current

0.1~100A

Output Power

12KW

Power Supply Stability

≦ 0.2%+10mV

Load Stability

≦ 0.2%+30mV

Ripple

≤ 0.5%+10mV( rms)

 

Voltage Value Display

4-digit display meter  Accuracy: ±0.3%FS + 3 digits (10%-100% of rated value)

Display format: 0.000V-9.999V; 0.00V-99.99V; 0.0V-999.9V

 

Current Value Display

4-digit display Accuracy: ±0.3% FS + 3 digits (10%-100% of rated value)

Display format: 0.000A-9.999A; 0.00A-99.99A; 0.0A-999.9A

Menu Display

64 x 128 dot matrix LCD display

Output Overvoltage Protection

The menu allows you to set O.V.P. (Over-Voltage Protection) parameters; the protection value can be set

arbitrarily, and the output will be shut off after protection is triggered.

Output Overcurrent

Protection

The menu allows you to set O.I.P. protection; the protection value can be set arbitrarily, and the output will beshut off after protection is triggered.

Over-Temperature Protection

Built-in OTP (Over-Temperature Protection) with a protection value of 85℃ ± 5% (heatsink temperature); output is shut off after protection is triggered.

Voltage Setting

Menu settings, input via keyboard or encoder knob.

Current Setting

Menu settings, input via keyboard or encoder knob.

Control Interface

Standard analog signal output, RS-485 control interface.

Output Polarity

The positive (+) and negative (-) outputs can be grounded arbitrarily.

Cooling Method

Forced air cooling

Operating Environment

Designed for indoor use; temperature: 0℃ to 40℃ ; humidity: 10% to 85% RH

Storage Environment

Temperature: -20℃ ~ 70℃ ; Humidity: 10% ~ 90% RH

Note: All values are typical values; therefore, these values may be exceeded under different load conditions or other circumstances. Accuracy is measured with voltage sensing at the load terminal.  Due to temperature variations and component aging, the actual values may deviate from the rated values.



Serial Number

Model

Input

Voltage (V)

Output

Voltage (V)

Output

Current (A)

Power (W)

Dimensions/MM

(H*W*L)

NeWeight (KG

Gross Weight

(KG)

1

IPS-ATDP62000

380VAC

6VDC

2000A

12KW

650*430*350

55

70

2

IPS-ATDP81500

380VAC

8VDC

1500A

12KW

650*430*350

55

70

3

IPS-ATDP101200

380VAC

10VDC

1200A

12KW

650*430*264

34

44

4

IPS-ATDP121000

380VAC

12VDC

1000A

12KW

650*430*264

34

44

5

IPS-ATDP15800

380VAC

15VDC

800A

12KW

650*430*264

33

43

6

IPS-ATDP16750

380VAC

16VDC

750A

12KW

650*430*264

33

43

7

IPS-ATDP20600

380VAC

20VDC

600A

12KW

650*430*264

33

43

8

IPS-ATDP24500

380VAC

24VDC

500A

12KW

650*430*264

33

43

9

IPS-ATDP25480

380VAC

25VDC

480A

12KW

650*430*264

33

43

10

IPS-ATDP30400

380VAC

30VDC

400A

12KW

650*430*264

33

43

11

IPS-ATDP32375

380VAC

32VDC

375A

12KW

650*430*264

33

43

12

IPS-ATDP40300

380VAC

40VDC

300A

12KW

650*430*264

33

43

13

IPS-ATDP48250

380VAC

48VDC

250A

12KW

650*430*264

33

43

14

IPS-ATDP50240

380VAC

50VDC

240A

12KW

650*430*264

33

43

15

IPS-ATDP60200

380VAC

60VDC

200A

12KW

650*430*264

33

43

16

IPS-ATDP75160

380VAC

75VDC

160A

12KW

650*430*264

33

43

17

IPS-ATDP80150

380VAC

80VDC

150A

12KW

650*430*264

33

43

18

IPS-ATDP96125

380VAC

96VDC

125A

12KW

650*430*264

32

42

19

IPS-ATDP100120

380VAC

100VDC

120A

12KW

650*430*264

32

42

20

IPS-ATDP120100

380VAC

120VDC

100A

12KW

650*430*264

32

42

21

IPS-ATDP12596

380VAC

125VDC

96A

12KW

650*430*264

32

42

22

IPS-ATDP15080

380VAC

150VDC

80A

12KW

650*430*264

32

42

23

IPS-ATDP16075

380VAC

160VDC

75A

12KW

650*430*264

32

42

24

IPS-ATDP20060

380VAC

200VDC

60A

12KW

650*430*264

32

42

25

IPS-ATDP24050

380VAC

240VDC

50A

12KW

650*430*264

32

42

26

IPS-ATDP25048

380VAC

250VDC

48A

12KW

650*430*264

32

42

27

IPS-ATDP30040

380VAC

300VDC

40A

12KW

650*430*264

32

42

28

IPS-ATDP37532

380VAC

375VDC

32A

12KW

650*430*264

32

42

29

IPS-ATDP40030

380VAC

400VDC

30A

12KW

650*430*264

32

42

30

IPS-ATDP48025

380VAC

480VDC

25A

12KW

650*430*264

32

42

31

IPS-ATDP50024

380VAC

500VDC

24A

12KW

650*430*264

32

42

32

IPS-ATDP60020

380VAC

600VDC

20A

12KW

650*430*264

32

42

33

IPS-ATDP75016

380VAC

750VDC

16A

12KW

650*430*264

32

42

34

IPS-ATDP80015

380VAC

800VDC

15A

12KW

650*430*264

32

42

35

IPS-ATDP96012.5

380VAC

960VDC

12.5A

12KW

650*430*264

32

42

36

IPS-ATDP100012

380VAC

1000VDC

12A

12KW

650*430*264

32

42

37

IPS-ATDP120010

380VAC

1200VDC

10A

12KW

650*430*264

32

42

38

IPS-ATDP15008

380VAC

1500VDC

8A

12KW

650*430*264

32

42

39

IPS-ATDP20006

380VAC

2000VDC

6A

12KW

650*430*264

32

42

40

IPS-ATDP24005

380VAC

2400VDC

5A

12KW

650*430*264

32

42

41

IPS-ATDP30004

380VAC

3000VDC

4A

12KW

650*430*350

55

70

            


                        Functional Device Description-Front


       image.png

image.png

Instructions

1. LCD display: Human-machine interaction interface, displaying Chinese menu;

2. Keyboard: Function keys and number keys;

3. Digital encoder: Can be used as an input substitute for the keyboard;

4. OUTPUT: This indicator light is on when there is output from the power supply;

5. "C.V" Status Indicator: Steady on indicates that the DC power supply is operating in constant voltage mode.

6. "C.C" Status Indicator: Steady on indicates that the DC power supply is operating in constant current (or current limiting) mode.

7. REMOTE Indicator: Remote control indicator, this light is on when remote control is active;

8. OV Indicator: Overvoltage protection indicator, this light is on during overvoltage conditions;

9. OI Indicator: Overcurrent protection indicator, this light is on during overcurrent conditions;

10. OT Indicator: Overtemperature protection indicator, this light is on during overtemperature conditions;

11. SHORT: Short circuit indicator, this light is on when the power supply is in a short circuit state;

12. Power Switch: Used to start and shut down


              

                        Functional Device Description-Back


             

                 

image.png

                         

image.png


WhatsApp
Wechat
Contact Us
Your Name:
Your Email:
Your Message:
This website uses cookies to enhance user experience and to analyze performance and traffic on our website.
We also share information about your use of our site with our social media, advertising and analytics partners.
Do Not Sell My Personal Information
Accept Cookies