Product Categories

IPS-ATDP101500 15KW Adjustable DC Laboratory Supply Paper Color & Gloss Meter Paper Water Absorption Tester
① AC INPUT: Three-phase 380VAC±10% 50/60HZ ② DC OUTPUT:0~10VDC, 0.1~1500A ③ Max power:15KW ④ Machine size:L350W430H650(MM) ⑤ NW: 55.0KG, GW: 70.0KG ⑥ Voltage indicator: Including ⑦ Current indicator: Including ⑧ Communication: RS485*1 ⑨ Cooling Method: Air cooling ⑩ Protection: lower voltage, over voltage, over current, short circuit, overheating Wechat Number/Whatsapp ID: +86-18928830209 Email: info@idealplusing.com Office telephone number:+86-20-89282095
Datasheet: Download


AC Input

Single-phase 220V ±10% or three-phase 380V ±10%

Frequency: 50Hz/60Hz

Model

IPS-ATDP101500

Output Voltage

0~10VDC

Output Current

0.1~1500A

Output Power

15KW

Power Supply Stability

≦ 0.2%+10mV

Load Stability

≦ 0.2%+30mV

Ripple

≤ 0.5%+10mV( rms)

 

Voltage Value Display

4-digit display meter  Accuracy: ±0.3%FS + 3 digits (10%-100% of rated value)

Display format: 0.000V-9.999V; 0.00V-99.99V; 0.0V-999.9V

 

Current Value Display

4-digit display Accuracy: ±0.3% FS + 3 digits (10%-100% of rated value)

Display format: 0.000A-9.999A; 0.00A-99.99A; 0.0A-999.9A

Menu Display

64 x 128 dot matrix LCD display

Output Overvoltage Protection

The menu allows you to set O.V.P. (Over-Voltage Protection) parameters; the protection value can be set

arbitrarily, and the output will be shut off after protection is triggered.

Output Overcurrent

Protection

The menu allows you to set O.I.P. protection; the protection value can be set arbitrarily, and the output will beshut off after protection is triggered.

Over-Temperature Protection

Built-in OTP (Over-Temperature Protection) with a protection value of 85℃ ± 5% (heatsink temperature); output is shut off after protection is triggered.

Voltage Setting

Menu settings, input via keyboard or encoder knob.

Current Setting

Menu settings, input via keyboard or encoder knob.

Control Interface

Standard analog signal output, RS-485 control interface.

Output Polarity

The positive (+) and negative (-) outputs can be grounded arbitrarily.

Cooling Method

Forced air cooling

Operating Environment

Designed for indoor use; temperature: 0℃ to 40℃ ; humidity: 10% to 85% RH

Storage Environment

Temperature: -20℃ ~ 70℃ ; Humidity: 10% ~ 90% RH

Note: All values are typical values; therefore, these values may be exceeded under different load conditions or other circumstances. Accuracy is measured with voltage sensing at the load terminal.  Due to temperature variations and component aging, the actual values may deviate from the rated values.



Serial Number

Model

Input

Voltage (V)

Output

Voltage (V)

Output

Current (A)

Power (W)

Dimensions/MM

(H*W*L)

Net Weight (KG)

Gross Weight

(KG

1

IPS-ATDP101500

380VAC

10VDC

1500A

15KW

650*430*350

55

70

2

IPS-ATDP121250

380VAC

12VDC

1250A

15KW

650*430*350

55

70

3

IPS-ATDP151000

380VAC

15VDC

1000A

15KW

650*430*264

33

43

4

IPS-ATDP20750

380VAC

20VDC

750A

15KW

650*430*264

33

43

5

IPS-ATDP24625

380VAC

24VDC

625A

15KW

650*430*264

33

43

6

IPS-ATDP25600

380VAC

25VDC

600A

15KW

650*430*264

33

43

7

IPS-ATDP30500

380VAC

30VDC

500A

15KW

650*430*264

33

43

8

IPS-ATDP40375

380VAC

40VDC

375A

15KW

650*430*264

33

43

9

IPS-ATDP48312.5

380VAC

48VDC

312.5A

15KW

650*430*264

33

43

10

IPS-ATDP50300

380VAC

50VDC

300A

15KW

650*430*264

33

43

11

IPS-ATDP60250

380VAC

60VDC

250A

15KW

650*430*264

33

43

12

IPS-ATDP75200

380VAC

75VDC

200A

15KW

650*430*264

33

43

13

IPS-ATDP80187.5

380VAC

80VDC

187.5A

15KW

650*430*264

33

43

14

IPS-ATDP100150

380VAC

100VDC

150A

15KW

650*430*264

33

43

15

IPS-ATDP120125

380VAC

120VDC

125A

15KW

650*430*264

32

42

16

IPS-ATDP125120

380VAC

125VDC

120A

15KW

650*430*264

32

42

17

IPS-ATDX150100

380VAC

150VDC

100A

15KW

650*430*264

32

42

18

IPS-ATDP20075

380VAC

200VDC

75A

15KW

650*430*264

32

42

19

IPS-ATDP25060

380VAC

250VDC

60A

15KW

650*430*264

32

42

20

IPS-ATDP30050

380VAC

300VDC

50A

15KW

650*430*264

32

42

21

IPS-ATDP37540

380VAC

375VDC

40A

15KW

650*430*264

32

42

22

IPS-ATDP50030

380VAC

500VDC

30A

15KW

650*430*264

32

42

23

IPS-ATDP60025

380VAC

600VDC

25A

15KW

650*430*264

32

42

24

IPS-ATDP62524

380VAC

625VDC

24A

15KW

650*430*264

32

42

25

IPS-ATDP75020

380VAC

750VDC

20A

15KW

650*430*264

32

42

26

IPS-ATDP100015

380VAC

1000VDC

15A

15KW

650*430*264

32

42

27

IPS-ATDP125012

380VAC

1250VDC

12A

15KW

650*430*264

32

42

28

IPS-ATDP150010

380VAC

1500VDC

10A

15KW

650*430*264

32

42

29

IPS-ATDP18758

380VAC

1875VDC

8A

15KW

650*430*264

32

42

30

IPS-ATDP25006

380VAC

2500VDC

6A

15KW

650*430*264

32

42

31

IPS-ATDP30005

380VAC

3000VDC

5A

15KW

650*430*264

32

42

32

IPS-ATDP37504

380VAC

3750VDC

4A

15KW

650*430*264

34

44

33

IPS-ATDP50003

380VAC

5000VDC

3A

15KW

650*430*264

34

44

            


                        Functional Device Description-Front


       image.png

image.png

Instructions

1. LCD display: Human-machine interaction interface, displaying Chinese menu;

2. Keyboard: Function keys and number keys;

3. Digital encoder: Can be used as an input substitute for the keyboard;

4. OUTPUT: This indicator light is on when there is output from the power supply;

5. "C.V" Status Indicator: Steady on indicates that the DC power supply is operating in constant voltage mode.

6. "C.C" Status Indicator: Steady on indicates that the DC power supply is operating in constant current (or current limiting) mode.

7. REMOTE Indicator: Remote control indicator, this light is on when remote control is active;

8. OV Indicator: Overvoltage protection indicator, this light is on during overvoltage conditions;

9. OI Indicator: Overcurrent protection indicator, this light is on during overcurrent conditions;

10. OT Indicator: Overtemperature protection indicator, this light is on during overtemperature conditions;

11. SHORT: Short circuit indicator, this light is on when the power supply is in a short circuit state;

12. Power Switch: Used to start and shut down


              

                        Functional Device Description-Back


             

                 

image.png

                         

image.png


WhatsApp
Wechat
Contact Us
Your Name:
Your Email:
Your Message:
This website uses cookies to enhance user experience and to analyze performance and traffic on our website.
We also share information about your use of our site with our social media, advertising and analytics partners.
Do Not Sell My Personal Information
Accept Cookies