Product Categories

IPS-ATDP100020 20KW Adjustable DC Laboratory Supply Parking Barrier System Livestock Weighing Scale
① AC INPUT: Three-phase 380VAC±10% 50/60HZ ② DC OUTPUT:0~1000VDC, 0.1~20A ③ Max power:20KW ④ Machine size:L264W430H650(MM) ⑤ NW: 33.0KG, GW: 43.0KG ⑥ Voltage indicator: Including ⑦ Current indicator: Including ⑧ Communication: RS485*1 ⑨ Cooling Method: Air cooling ⑩ Protection: lower voltage, over voltage, over current, short circuit, overheating Wechat Number/Whatsapp ID: +86-18928830209 Email: info@idealplusing.com Office telephone number:+86-20-89282095
Datasheet: Download


AC Input

Single-phase 220V ±10% or three-phase 380V ±10%

Frequency: 50Hz/60Hz

Model

IPS-ATDP100020

Output Voltage

0~1000VDC

Output Current

0.1~20A

Output Power

20KW

Power Supply Stability

≦ 0.2%+10mV

Load Stability

≦ 0.2%+30mV

Ripple

≤ 0.5%+10mV( rms)

 

Voltage Value Display

4-digit display meter  Accuracy: ±0.3%FS + 3 digits (10%-100% of rated value)

Display format: 0.000V-9.999V; 0.00V-99.99V; 0.0V-999.9V

 

Current Value Display

4-digit display Accuracy: ±0.3% FS + 3 digits (10%-100% of rated value)

Display format: 0.000A-9.999A; 0.00A-99.99A; 0.0A-999.9A

Menu Display

64 x 128 dot matrix LCD display

Output Overvoltage Protection

The menu allows you to set O.V.P. (Over-Voltage Protection) parameters; the protection value can be set

arbitrarily, and the output will be shut off after protection is triggered.

Output Overcurrent

Protection

The menu allows you to set O.I.P. protection; the protection value can be set arbitrarily, and the output will beshut off after protection is triggered.

Over-Temperature Protection

Built-in OTP (Over-Temperature Protection) with a protection value of 85℃ ± 5% (heatsink temperature); output is shut off after protection is triggered.

Voltage Setting

Menu settings, input via keyboard or encoder knob.

Current Setting

Menu settings, input via keyboard or encoder knob.

Control Interface

Standard analog signal output, RS-485 control interface.

Output Polarity

The positive (+) and negative (-) outputs can be grounded arbitrarily.

Cooling Method

Forced air cooling

Operating Environment

Designed for indoor use; temperature: 0℃ to 40℃ ; humidity: 10% to 85% RH

Storage Environment

Temperature: -20℃ ~ 70℃ ; Humidity: 10% ~ 90% RH

Note: All values are typical values; therefore, these values may be exceeded under different load conditions or other circumstances. Accuracy is measured with voltage sensing at the load terminal.  Due to temperature variations and component aging, the actual values may deviate from the rated values.


Serial Number

Model

Input

Voltage (V)

Output

Voltage (V)

Output

Current (A)

Power (W)

Dimensions/MM

(H*W*L)

Net Weight (KG)

Gross Weight

(KG)

1

IPS-ATDP102000

380VAC

10VDC

2000A

20KW

650*430*350

55

70

2

IPS-ATDP161250

380VAC

16VDC

1250A

20KW

650*430*264

34

44

3

IPS-ATDP201000

380VAC

20VDC

1000A

20KW

650*430*264

34

44

4

IPS-ATDP25800

380VAC

25VDC

800A

20KW

650*430*264

34

44

5

IPS-ATDP32625

380VAC

32VDC

625A

20KW

650*430*264

34

44

6

IPS-ATDP40500

380VAC

40VDC

500A

20KW

650*430*264

34

44

7

IPS-ATDP50400

380VAC

50VDC

400A

20KW

650*430*264

34

44

8

IPS-ATDP64312

380VAC

64VDC

312A

20KW

650*430*264

33

43

9

IPS-ATDP80250

380VAC

80VDC

250A

20KW

650*430*264

33

43

10

IPS-ATDP100200

380VAC

100VDC

200A

20KW

650*430*264

33

43

11

IPS-ATDP125160

380VAC

125VDC

160A

20KW

650*430*264

33

43

12

IPS-ATDP128156

380VAC

128VDC

156A

20KW

650*430*264

33

43

13

IPS-ATDP160125

380VAC

160VDC

125A

20KW

650*430*264

33

43

14

IPS-ATDP200100

380VAC

200VDC

100A

20KW

650*430*264

33

43

15

IPS-ATDP25080

380VAC

250VDC

80A

20KW

650*430*264

33

43

16

IPS-ATDP25678

380VAC

256VDC

78A

20KW

650*430*264

32

43

17

IPS-ATDP40050

380VAC

400VDC

50A

20KW

650*430*264

32

43

18

IPS-ATDP50040

380VAC

500VDC

40A

20KW

650*430*264

32

43

19

IPS-ATDP62532

380VAC

625VDC

32A

20KW

650*430*264

32

43

20

IPS-ATDP80025

380VAC

800VDC

25A

20KW

650*430*264

32

43

21

IPS-ATDP100020

380VAC

1000VDC

20A

20KW

650*430*264

32

43

22

IPS-ATDP125016

380VAC

1250VDC

16A

20KW

650*430*264

32

43

23

IPS-ATDP200010

380VAC

2000VDC

10A

20KW

650*430*264

34

44

24

IPS-ATDP25008

380VAC

2500VDC

8A

20KW

650*430*264

34

44

25

IPS-ATDP40005

380VAC

4000VDC

5A

20KW

650*430*350

55

70

26

IPS-ATDP50004

380VAC

5000VDC

4A

20KW

650*430*350

55

70

            


                        Functional Device Description-Front


       image.png

image.png

Instructions

1. LCD display: Human-machine interaction interface, displaying Chinese menu;

2. Keyboard: Function keys and number keys;

3. Digital encoder: Can be used as an input substitute for the keyboard;

4. OUTPUT: This indicator light is on when there is output from the power supply;

5. "C.V" Status Indicator: Steady on indicates that the DC power supply is operating in constant voltage mode.

6. "C.C" Status Indicator: Steady on indicates that the DC power supply is operating in constant current (or current limiting) mode.

7. REMOTE Indicator: Remote control indicator, this light is on when remote control is active;

8. OV Indicator: Overvoltage protection indicator, this light is on during overvoltage conditions;

9. OI Indicator: Overcurrent protection indicator, this light is on during overcurrent conditions;

10. OT Indicator: Overtemperature protection indicator, this light is on during overtemperature conditions;

11. SHORT: Short circuit indicator, this light is on when the power supply is in a short circuit state;

12. Power Switch: Used to start and shut down


              

                        Functional Device Description-Back


             

                 

image.png

                         

image.png


Wechat
Contact Us
Your Name:
Your Email:
Your Message:
This website uses cookies to enhance user experience and to analyze performance and traffic on our website.
We also share information about your use of our site with our social media, advertising and analytics partners.
Do Not Sell My Personal Information
Accept Cookies