Product Categories

IPS-ATDP200125 25KW Adjustable DC Laboratory Supply Network Hub Power Supply Fiber Media Converter
① AC INPUT: Three-phase 380VAC±10% 50/60HZ ② DC OUTPUT: 0~200VDC, 0.1~125A ③ Max power:25KW ④ Machine size:L264W430H650(MM) ⑤ NW: 34.0KG, GW: 44.0KG ⑥ Voltage indicator: Including ⑦ Current indicator: Including ⑧ Communication: RS485*1 ⑨ Cooling Method: Air cooling ⑩ Protection: lower voltage, over voltage, over current, short circuit, overheating Wechat Number/Whatsapp ID: +86-18928830209 Email: info@idealplusing.com Office telephone number:+86-20-89282095
Datasheet: Download


AC Input

Single-phase 220V ±10% or three-phase 380V ±10%

Frequency: 50Hz/60Hz

Model

IPS-ATDP200125

Output Voltage

0~200VDC

Output Current

0.1~125A

Output Power

25KW

Power Supply Stability

≦ 0.2%+10mV

Load Stability

≦ 0.2%+30mV

Ripple

≤ 0.5%+10mV( rms)

 

Voltage Value Display

4-digit display meter  Accuracy: ±0.3%FS + 3 digits (10%-100% of rated value)

Display format: 0.000V-9.999V; 0.00V-99.99V; 0.0V-999.9V

 

Current Value Display

4-digit display Accuracy: ±0.3% FS + 3 digits (10%-100% of rated value)

Display format: 0.000A-9.999A; 0.00A-99.99A; 0.0A-999.9A

Menu Display

64 x 128 dot matrix LCD display

Output Overvoltage Protection

The menu allows you to set O.V.P. (Over-Voltage Protection) parameters; the protection value can be set

arbitrarily, and the output will be shut off after protection is triggered.

Output Overcurrent

Protection

The menu allows you to set O.I.P. protection; the protection value can be set arbitrarily, and the output will beshut off after protection is triggered.

Over-Temperature Protection

Built-in OTP (Over-Temperature Protection) with a protection value of 85℃ ± 5% (heatsink temperature); output is shut off after protection is triggered.

Voltage Setting

Menu settings, input via keyboard or encoder knob.

Current Setting

Menu settings, input via keyboard or encoder knob.

Control Interface

Standard analog signal output, RS-485 control interface.

Output Polarity

The positive (+) and negative (-) outputs can be grounded arbitrarily.

Cooling Method

Forced air cooling

Operating Environment

Designed for indoor use; temperature: 0℃ to 40℃ ; humidity: 10% to 85% RH

Storage Environment

Temperature: -20℃ ~ 70℃ ; Humidity: 10% ~ 90% RH

Note: All values are typical values; therefore, these values may be exceeded under different load conditions or other circumstances. Accuracy is measured with voltage sensing at the load terminal.  Due to temperature variations and component aging, the actual values may deviate from the rated values.


Serial Number

Model

Input

Voltage (V)

Output

Voltage (V)

Output

Current (A)

Power (W)

Dimensions/MM

(H*W*L)

Net Weight (KG)

Gross Weight

(KG)

1

IPS-ATDP102500

380VAC

10VDC

2500A

25KW

650*430*350

65

75

2

IPS-ATDP201250

380VAC

20VDC

1250A

25KW

650*430*264

34

44

3

IPS-ATDP251000

380VAC

25VDC

1000A

25KW

650*430*264

34

44

4

IPS-ATDP40625

380VAC

40VDC

625A

25KW

650*430*264

34

44

5

IPS-ATDP50500

380VAC

50VDC

500A

25KW

650*430*264

34

44

6

IPS-ATDP100250

380VAC

100VDC

250A

25KW

650*430*264

34

44

7

IPS-ATDP125200

380VAC

125VDC

200A

25KW

650*430*264

34

44

8

IPS-ATDP200125

380VAC

200VDC

125A

25KW

650*430*264

34

44

9

IPS-ATDP250100

380VAC

250VDC

100A

25KW

650*430*264

34

44

10

IPS-ATDP50050

380VAC

500VDC

50A

25KW

650*430*264

33

43

11

IPS-ATDP62540

380VAC

625VDC

40A

25KW

650*430*264

33

43

12

IPS-ATDP100025

380VAC

1000VDC

25A

25KW

650*430*264

33

43

13

IPS-ATDP125020

380VAC

1250VDC

20A

25KW

650*430*264

33

43

14

IPS-ATDP250010

380VAC

2500VDC

10A

25KW

650*430*264

33

43

15

IPS-ATDP31258

380VAC

3125VDC

8A

25KW

650*430*350

55

70

            


                        Functional Device Description-Front


       image.png

image.png

Instructions

1. LCD display: Human-machine interaction interface, displaying Chinese menu;

2. Keyboard: Function keys and number keys;

3. Digital encoder: Can be used as an input substitute for the keyboard;

4. OUTPUT: This indicator light is on when there is output from the power supply;

5. "C.V" Status Indicator: Steady on indicates that the DC power supply is operating in constant voltage mode.

6. "C.C" Status Indicator: Steady on indicates that the DC power supply is operating in constant current (or current limiting) mode.

7. REMOTE Indicator: Remote control indicator, this light is on when remote control is active;

8. OV Indicator: Overvoltage protection indicator, this light is on during overvoltage conditions;

9. OI Indicator: Overcurrent protection indicator, this light is on during overcurrent conditions;

10. OT Indicator: Overtemperature protection indicator, this light is on during overtemperature conditions;

11. SHORT: Short circuit indicator, this light is on when the power supply is in a short circuit state;

12. Power Switch: Used to start and shut down


              

                        Functional Device Description-Back


             

                 

image.png

                         

image.png


Wechat
Contact Us
Your Name:
Your Email:
Your Message:
This website uses cookies to enhance user experience and to analyze performance and traffic on our website.
We also share information about your use of our site with our social media, advertising and analytics partners.
Do Not Sell My Personal Information
Accept Cookies