Product Categories

IPS-ATDP240012.5 30KW Adjustable DC Laboratory Supply Mixed Domain Oscilloscope Power Wafer Inspection Power Supply
① AC INPUT: Three-phase 380VAC±10% 50/60HZ ② DC OUTPUT:0~2400VDC, 0.1~12.5A ③ Max power:30KW ④ Machine size:L264W430H650(MM) ⑤ NW: 32.0KG, GW: 43.0KG ⑥ Voltage indicator: Including ⑦ Current indicator: Including ⑧ Communication: RS485*1 ⑨ Cooling Method: Air cooling ⑩ Protection: lower voltage, over voltage, over current, short circuit, overheating Wechat Number/Whatsapp ID: +86-18928830209 Email: info@idealplusing.com Office telephone number:+86-20-89282095
Datasheet: Download


AC Input

Single-phase 220V ±10% or three-phase 380V ±10%

Frequency: 50Hz/60Hz

Model

IPS-ATDP240012.5

Output Voltage

0~2400VDC

Output Current

0.1~12.5A

Output Power

30KW

Power Supply Stability

≦ 0.2%+10mV

Load Stability

≦ 0.2%+30mV

Ripple

≤ 0.5%+10mV( rms)

 

Voltage Value Display

4-digit display meter  Accuracy: ±0.3%FS + 3 digits (10%-100% of rated value)

Display format: 0.000V-9.999V; 0.00V-99.99V; 0.0V-999.9V

 

Current Value Display

4-digit display Accuracy: ±0.3% FS + 3 digits (10%-100% of rated value)

Display format: 0.000A-9.999A; 0.00A-99.99A; 0.0A-999.9A

Menu Display

64 x 128 dot matrix LCD display

Output Overvoltage Protection

The menu allows you to set O.V.P. (Over-Voltage Protection) parameters; the protection value can be set

arbitrarily, and the output will be shut off after protection is triggered.

Output Overcurrent

Protection

The menu allows you to set O.I.P. protection; the protection value can be set arbitrarily, and the output will beshut off after protection is triggered.

Over-Temperature Protection

Built-in OTP (Over-Temperature Protection) with a protection value of 85℃ ± 5% (heatsink temperature); output is shut off after protection is triggered.

Voltage Setting

Menu settings, input via keyboard or encoder knob.

Current Setting

Menu settings, input via keyboard or encoder knob.

Control Interface

Standard analog signal output, RS-485 control interface.

Output Polarity

The positive (+) and negative (-) outputs can be grounded arbitrarily.

Cooling Method

Forced air cooling

Operating Environment

Designed for indoor use; temperature: 0℃ to 40℃ ; humidity: 10% to 85% RH

Storage Environment

Temperature: -20℃ ~ 70℃ ; Humidity: 10% ~ 90% RH

Note: All values are typical values; therefore, these values may be exceeded under different load conditions or other circumstances. Accuracy is measured with voltage sensing at the load terminal.  Due to temperature variations and component aging, the actual values may deviate from the rated values.




Serial Number

Model

Input

Voltage (V)

Output

Voltage (V)

Output

Current (A)

Power (W)

Dimensions/MM

(H*W*L)

Net Weight (KG)

Gross Weight

(KG)

1

IPS-ATDP122500

380VAC

12VDC

2500A

30KW

650*430*350

65

75

2

IPS-ATDP152000

380VAC

15VDC

2000A

30KW

650*430*350

65

75

3

IPS-ATDP161875

380VAC

16VDC

1875A

30KW

650*430*350

55

70

4

IPS-ATDP201500

380VAC

20VDC

1500A

30KW

650*430*350

55

70

5

IPS-ATDP241250

380VAC

24VDC

1250A

30KW

650*430*264

34

44

6

IPS-ATDP251200

380VAC

25VDC

1200A

30KW

650*430*264

34

44

7

IPS-ATDP301000

380VAC

30VDC

1000A

30KW

650*430*264

34

44

8

IPS-ATDP40750

380VAC

40VDC

750A

30KW

650*430*264

34

44

9

IPS-ATDP48625

380VAC

48VDC

625A

30KW

650*430*264

33

43

10

IPS-ATDP50600

380VAC

50VDC

600A

30KW

650*430*264

33

43

11

IPS-ATDP60500

380VAC

60VDC

500A

30KW

650*430*264

33

43

12

IPS-ATDP75400

380VAC

75VDC

400A

30KW

650*430*264

33

43

13

IPS-ATDP80375

380VAC

80VDC

375A

30KW

650*430*264

33

43

14

IPS-ATDP100300

380VAC

100VDC

300A

30KW

650*430*264

33

43

15

IPS-ATDP120250

380VAC

120VDC

250A

30KW

650*430*264

33

43

16

IPS-ATDP125240

380VAC

125VDC

240A

30KW

650*430*264

33

43

17

IPS-ATDP150200

380VAC

150VDC

200A

30KW

650*430*264

33

43

18

IPS-ATDP200150

380VAC

200VDC

150A

30KW

650*430*264

33

43

19

IPS-ATDP240125

380VAC

240VDC

125A

30KW

650*430*264

33

43

20

IPS-ATDP250120

380VAC

250VDC

120A

30KW

650*430*264

33

43

21

IPS-ATDP300100

380VAC

300VDC

100A

30KW

650*430*264

33

43

22

IPS-ATDP37580

380VAC

375VDC

80A

30KW

650*430*264

33

43

23

IPS-ATDP40075

380VAC

400VDC

75A

30KW

650*430*264

32

43

24

IPS-ATDP50060

380VAC

500VDC

60A

30KW

650*430*264

32

43

25

IPS-ATDP60050

380VAC

600VDC

50A

30KW

650*430*264

32

43

26

IPS-ATDP62548

380VAC

625VDC

48A

30KW

650*430*264

32

43

27

IPS-ATDP75040

380VAC

750VDC

40A

30KW

650*430*264

32

43

28

IPS-ATDP100030

380VAC

1000VDC

30A

30KW

650*430*264

32

43

29

IPS-ATDP120025

380VAC

1200VDC

25A

30KW

650*430*264

32

43

30

IPS-ATDP125024

380VAC

1250VDC

24A

30KW

650*430*264

32

43

31

IPS-ATDP150020

380VAC

1500VDC

20A

30KW

650*430*264

33

43

32

IPS-ATDP200015

380VAC

2000VDC

15A

30KW

650*430*264

33

43

33

IPS-ATDP240012.5

380VAC

2400VDC

12.5A

30KW

650*430*264

33

43

34

IPS-ATDP250012

380VAC

2500VDC

12A

30KW

650*430*350

55

70

35

IPS-ATDP300010

380VAC

3000VDC

10A

30KW

650*430*350

55

70

36

IPS-ATDP37508

380VAC

3750VDC

8A

30KW

650*430*350

55

70


            


                        Functional Device Description-Front


       image.png

image.png

Instructions

1. LCD display: Human-machine interaction interface, displaying Chinese menu;

2. Keyboard: Function keys and number keys;

3. Digital encoder: Can be used as an input substitute for the keyboard;

4. OUTPUT: This indicator light is on when there is output from the power supply;

5. "C.V" Status Indicator: Steady on indicates that the DC power supply is operating in constant voltage mode.

6. "C.C" Status Indicator: Steady on indicates that the DC power supply is operating in constant current (or current limiting) mode.

7. REMOTE Indicator: Remote control indicator, this light is on when remote control is active;

8. OV Indicator: Overvoltage protection indicator, this light is on during overvoltage conditions;

9. OI Indicator: Overcurrent protection indicator, this light is on during overcurrent conditions;

10. OT Indicator: Overtemperature protection indicator, this light is on during overtemperature conditions;

11. SHORT: Short circuit indicator, this light is on when the power supply is in a short circuit state;

12. Power Switch: Used to start and shut down


              

                        Functional Device Description-Back


             

                 

image.png

                         

image.png


Wechat
Contact Us
Your Name:
Your Email:
Your Message:
This website uses cookies to enhance user experience and to analyze performance and traffic on our website.
We also share information about your use of our site with our social media, advertising and analytics partners.
Do Not Sell My Personal Information
Accept Cookies