Product Categories

IPS-NDR-240-24 240W Ultra Thin DIN Rail Mounted 24V 10A For Industrial Control Drive Electric Cabinet Switch Power Supply
MODEL:IPS-NDR-240-24 Rail Power Supply 24v 240w SPECIFICATION: ① AC input: Single-phase 100-240VAC 50/60hz ② DC output: 24VDC,10A ③ Power: 240W ④ Dimension: 63*125.2*113.5MM ⑤ NW: 0.75KG

I. APPLICATION

Industrial control system

Semiconductor manufacturing equipment

Factory automation

Electromechanical Equipment

 

II. FEATURES

1

Protection type: Short circuit/over load/over voltage/over temperature

2

Natural air cooling

3

Can be installed on TS-35/7.5 or 15

4

EN61000-6-2 (EN50082-2) Industrial Immunity

5

100% full load aging

 

III. DESCRIPTION

The NDR-240 is designed with a metal casing, which is convenient for improving the heat dissipation consumption of the machine. The working efficiency is up to 89%. Under air circulation conditions, the entire series can work in ambient temperatures ranging from -20 ℃ to 70 ℃. It has a constant current mode overload protection function, suitable for various inductive or capacitive load applications. The complete protection function and industrial control equipment comply with GB4943 certification.

 

IV. ELECTRICAL SPECIFICATIONS

Model

NDR-240-24

NDR-240-48

Output

DC voltage

24V

48V

Rated current

10A

5A

Current range

0~10A

0~5A

Rated power

240W

240W

Ripple and noise (maximum) Note 2

150mVp-p

150mVp-p

Voltage adjustment range

24 ~ 28V

48 ~ 55V

Voltage accuracy note 3

±1.0%

±1.0%

Linear adjustment rate

±0.5%

±0.5%

Load adjustment rate

±1.0%

±1.0%

Start and rise time

1500ms , 100ms/230VAC & 3000ms ,  100ms/115VAC (At full load)

Hold time (Typ.)

28ms/230VAC  & 22ms/115VAC(At full load)

Input

Voltage range

209~245VAC

Frequency range

47 ~ 63Hz

Efficiency (Typ.)

89%

90%

AC current (Typ.)

2.5A/115VAC               1.3A/230VAC

Surge current (Typ)

20A/115VAC              35A/230VAC

Leakage current

<1mA/ 240VAC

Protection function

Over load

105% to 130% of rated output power

Protection mode: Constant current mode, which can automatically recover after removing abnormal load conditions

Over voltage

29 ~ 33V

56 ~ 65V

Protection mode: Turn off the output and resume normal output after power restart

Over Temperature

Turn off the output and resume normal output after power restart

Environment

operation temperature

-20~+70℃ (Please refer to the "Derating Curve")

Working humidity

20  ~ 95%  RH , No condensation

Storage temperature and humidity

-40  ~ +85℃ ,  10 ~ 95%  RH

temperature coefficient

±0 .03%/℃ (0~50℃)

Vibration

Component: 10~500Hz, 2G 10 minutes/cycle, X, Y, Z each 60 minutes; Installation: Compliant withIEC60068-2-6

Safety regulations and electromagnetic compatibility

Safety regulations

conform to GB4943

pressurization

I/P-O/P:3KVAC      I/P-FG:2KVAC       O/P-FG:0 .5KVAC

Insulation impedance

I/P-O/P ,  I/P-FG ,  O/P-FG:>100M  Ohms / 500VDC / 25℃/ 70%  RH

Electromagnetic compatibility emission

Conform to EN55032  (CISPR32) , EN61204-3 Class B , EN61000-3-2 ,-3 , EAC TP TC 020 ,CNS13438

Electromagnetic compatibility immunity

conform to EN61000-4-2,3,4,5,6,8, 11, EN55024, EN61000-6 2 (EN50082-2), EN61204-3,A Grade heavy industry standard, EAC TP TC 020

Others

MTBF

≥230 .2K hrs .  MIL- HDBK-217F (25℃)

Size

63*125.2*113.5 (MM)

Package

0.75Kg

Notes

1. Unless otherwise specified, all specifications and parameters are measured at 230VAC input, rated load, and 25 ℃ ambient temperature.

2. Ripple and noise measurement method: Use a 12 "twisted pair with terminals connected in parallel with 0.1uf and 47uf capacitors, and measure at a bandwidth of 20MHZ.

3. Accuracy: including setting error, linear adjustment rate, and load adjustment rate.

4. The power supply should be considered as a part of the internal components of the system, and electromagnetic compatibility related confirmation should be conducted in conjunction with the terminal equipment.

5. Installation distance: When permanently loaded with full power, it is recommended to have a top distance of 40mm and a bottom distance of about 20mm, with a distance of 5mm on both sides. If the adjacent equipment is a heat source, the recommended space distance is 15mm.

6. Under low input voltage, it is necessary to derate the output. Please refer to the derating curve for details.

7. When the altitude exceeds 2000 meters (6500 feet), the ambient temperature of the fanless model decreases in proportion every 3.5 ℃/1000m, while the ambient temperature of the fanned model decreases in proportion every 5 ℃/1000m.