Product Categories

IDEALPLUSING IPS-DTAHV30K Renewable Energy Inverter for Solar System
MODEL:IPS-DTAHV30K High Voltage Three-phase Inverter SPECIFICATION: ① DC input: 150VDC ~ 750VDC ② AC output: 3-phase 380/400/415 VAC ③ Power: 27KW ④ Dimension:440*720*178MM ⑤ NW: 45KG We accept customized inverters to meet your specific requirements. With customized input and output voltage and current, our products range from 1V to 1000V and 1A to 1000A. We provide one-to-one customization service. You tell us your needs and we will recommend the best solution for you.

INTRODUCE

High-voltage three-phase inverter is a power conversion device that is mainly used to convert direct current (DC) into high-voltage three-phase alternating current (AC). It is widely used in large residential, small industrial and commercial photovoltaic energy storage systems, and home energy storage applications.


FEATURE

lEnergy saving and environmental protection: high input-output power factor, high efficiency.

lStrong load capacity: The output power factor is 0.9 , and there is no derating with leading power factor load.

lEasy to install: 19-inch rack design, 4U height, rear wiring installation, can be directly installed using industrial connectors or OT terminals.

lEasy to maintain: Full front maintenance allows for quick replacement of faulty parts.

lEasy to expand: Modular structure, easy to expand in parallel, supports up to four parallel systems.

lCommunication interface: Support MODBUS RTU and MODBUS TCP communication.

lFlexible application: supports 2-wire and 3-wire (with midpoint N) DC input, supports 3-wire and 4-wire (with N line) output, bypass is optional.


SPECIFICATIONS

Product model

Type

IPS-DTAHV30K

Work environment

Operating temperature

0~+40

Storage temperature

-40~+70

Relative humidity

0 ~90% (no condensation)

Cooling method

Forced air cooling, front air flow and rear air flow

Altitude

0 -3000 m, based on 3000 m , the maximum temperature of the specification decreases by 1 °c for every 200 m increase in altitude

Noise (1m)

55dB

Input characteristics (DC )

Rated input voltage

240/360VDC

Input dc voltage allowable range

150VDC ~ 750VDC

Input mode

Two or three wires with N wire

Input characteristics ( AC )

Bypass mode

Three-phase four-wire + ground wire / three-phase three-wire + ground wire;

Bypass voltage system

380/400/415VAC ;

Frequency system

5 0HZ/60HZ ;

Bypass voltage range

The upper limit can be set to : +10%, +15%, or +20% default : +1 0 % ;

The lower limit can be set : -10%, -20%, -30% or -40% ; default : - 1 0% ;

Bypass frequency range 

The range can be set to: +/- 10% or +/- 20% default : +/- 10% ;

Voltage switching range 

+10% of rated voltage amplitude;

Frequency tracking range 

+/- 0.5, 1, 2, 3HZ, 10% of rated frequency; default value : +/-2hz ;

Bypass overload capability 

380v system, bypass <= 60 a , long-term operation; there is an alarm for bypass overload;

Output characteristics ( AC )

Output mode

Three-phase four-wire + ground wire/three-phase three-wire + ground wire;

Power factor pf

0.9(optional 1)

Output power

27KW

Load power factor range

 Within the maximum power range, it can carry loads with a leading or lagging power factor of 0.5

Output rated voltage

380/400/415 VAC (line voltage)

Voltage accuracy

+/- 1% for balanced load; +/- 5% for unbalanced load

Output regulation 

+/- 5% of rated voltage

Voltage distortion

2 % (100 % linear load); <5 % ( 100% non-linear load)

Rated frequency

50HZ/ 60HZ

Frequency accuracy

+/- 0.3% of rated frequency

Load imbalance

Meet 100% unbalanced operation

Inverter overload capacity (tested at rated input)

Tested under rated dc input conditions:

<=105% load, continuous power supply;

105 ~ 125 % load, turn off the inverter for 10 minutes ;

125%~ 150 % load , turn off the inverter in 10 seconds;

>150 % load, 200ms shutdown

Amplitude dynamic response value

+/- 5.0% for 100% linear load step dynamics

Dynamic recovery time

< 20ms

Peak ratio

3:1

Switching time (optional)

Inverter to bypass: < 3 ms; bypass to inverter: <=10ms (can be set to 10-50ms)

Communication

RS232/RS485, TCP/IP, MODBUS RTU

System features

Operation mode

Support four parallel operation;

Incoming line

Back-end wiring, the port has strong adaptability and can meet the requirements of ot terminal or industrial connector wiring;

Dc inverter working efficiency

(tested at rated input)

75% load ≥ 96%; 50% load, ≥ 94%; 25% load ≥ 92%;

Efficiency in mains mode

>99.6%

Product reliability and safety

Mean time between failures (m tbf )

500,000 hours

Safety regulations

Meet CCC,CE

Dimensions and weight

1 9 inch standard rack mount, dimensions d*w*h (mm)

440*720*178

Net weight

45 KG


WhatsApp
Wechat
Contact Us
Your Name:
Your Email:
Your Message: