INTRODUCE
A AC/DC high voltage input power supply is a device that converts a high voltage DC power supply into a DC power supply of a different voltage level. They are widely used in a variety of applications
FEATURES
lUltra-small size, save space
lInput and output isolation
lUniversal input voltage: 85-264VAC/100-370VDC
lOutput overcurrent protection, short circuit protection
lThis series of products are widely used in industry, power, instrumentation, communication, smart home and other fields
SPECIFICATIONS
| Project | Condition | Minimum | Typical Value | Maximum | |
| 
 Input voltage range | AC input | 85VAC | 230VAC | 264VAC | |
| DC input | 100VDC | 310VDC | 370VDC | ||
| 
 Input Current | 230VAC | / | / | 160mA | |
| 115VAC | / | / | 270mA 
 | ||
| Output voltage accuracy 
 | Single output | / | ±2% | / | |
| Dual output, balanced load*2 | Main Road | ±2% | |||
| Auxiliary Road | / | ±10% | / | ||
| Linear regulation rate | Full load | / | ±1% 
 | / | |
| Load regulation rate | Single channel, 10%-100% load | / | ±3% | / | |
| 
 Dual output, 10%-100% balanced load*2 | Main Road | ±3% | |||
| Auxiliary Road | ±10% | ||||
| Output ripple and noise* | 20MHz bandwidth (peak-to-peak) 
 
 | / | 100mV 
 | / | |
| Short circuit protection | Can be short-circuited for a long time, self-recovery | ||||
| Output overcurrent protection | ≥110%Io, self-recovery | ||||
| Minimum load | 0 | / | / | ||
| Power-off hold time | / | 20ms | / | ||
| Operating temperature | -15℃ | / | +70℃ | ||
| Storage temperature | -40℃ | / | +105℃ | ||
| Storage humidity | / | / | 95%RH | ||
| Switching frequency | / | 65kHz | / | ||
| Insulation voltage | Input to output, test 60s, ≤5mA | 3000VAC | / | / | |
| MTBF | MIL-HDBK-217F@25℃ | 215000h | / | / | |
| Note: * Ripple and noise are tested using the parallel line test method (the oscilloscope probe is connected to the test point, and a 10μF high-frequency low-resistance electrolytic capacitor and a 0.1μF ceramic capacitor are connected in parallel at the test point). *2. Balanced load means that the output load of the main circuit and the auxiliary circuit changes in the same proportion. | |||||
MODEL LIST
| Model | Input voltage range | Output Power | Rated output voltage( V ) | Rated output current( mA ) | Size (Length * Width * Height) | 
| IPS25-V2S05 | 
 
 
 85-264 VAC /100-370 
 
 
 
 | 20W | 5VDC | 4000mA | 70.0*48.0*23.5 MM | 
| IPS25-V2S12 | 
 
 25W | 12VDC | 2100mA | ||
| IPS25-V2S15 | 15VDC | 1600mA | |||
| IPS25-V2S24 | 24VDC | 1050mA | |||
| IPS25-V2D05 | 20W | +5VDC | 2000mA | ||
| IPS25-V2D12 | 
 
 25W | +12VDC | 1050 mA | ||
| IPS25-V2D15 | +15VDC | 830 mA | |||
| IPS25-V2D24 | +24VDC | 520mA | 
 
         
        
 
         
                         
                        