Single-phase inverter power supply parameters | |||||||||||
Model | LNS*—D—*K | ||||||||||
Power (KVA) | 5 | 10 | 20 | 30 | 50 | 100 | 150 | 200 | |||
DC Input | Input voltage range | 40-850V The DC voltage range can be selected according to the power requirements; other voltages are available upon request. (850-1500V) | |||||||||
Bypass input | Allowable Input V Range | 220Vac±15%, other voltages available upon request | |||||||||
Input frequency range | 50/60Hz±5Hz, other frequencies available upon request | ||||||||||
Bypass transfer time | ≥200ms, customizable to <10ms | ||||||||||
Communication Output | Rated Output V | 220VAC other voltages available upon request | |||||||||
Rated Output Freq | 50/60Hz, other frequencies available upon request | ||||||||||
Output V Accuracy | ±1% | ||||||||||
Output Freq Accuracy | ±0.1% | ||||||||||
Rated Current (A) | 22.8 | 45.5 | 91 | 136.4 | 227.3 | 454.6 | 681.9 | 909.1 | |||
The rated current is calculated at an output voltage of AC 220V. | |||||||||||
THD (Waveform Distortion Rate) | <3% (linear load) | ||||||||||
Dynamic Response Time | 2ms (load 0-100%) | ||||||||||
Overload Capacity | 110% for 10 minutes, 200% for 3 seconds, customizable up to 400% for 1 second | ||||||||||
CF (Crest Factor) | 3:1 | ||||||||||
Max Inverter Efficiency | 96% | ||||||||||
WorkingEnvironment | Insulation Strength (In/Out) | 1500VAC,1 minute | |||||||||
Noise (at 1meter) | ≤65dB(1 meter away) | ||||||||||
Operating Ambient Temp | -10℃ to -50℃ Other temperatures can be customized | ||||||||||
Humidity | 0-90%, non-condensing | ||||||||||
Operating altitude (m) | ≤6000m, derating required above 2000 meters (1% derating for every 100 meters increase in altitude) | ||||||||||
Indicator lights | Bypass, Inversion (or Operation, Fault) | ||||||||||
Display method | Touchscreen/LED digital display | ||||||||||
Protection functions | It features multiple protection functions, including input reverse connection protection, input over/undervoltage protection, output overload/overcurrent protection, three-phase voltage imbalance protection, drive protection, and overheating protection. | ||||||||||
Emergency shutdown | Equipped with an emergency stop button. | ||||||||||
Protection level | IP20 (customizable to IP54) | ||||||||||
Three-phase inverter power supply parameters | |||||||||||
Model | LNS*—S—*K | ||||||||||
Power (KVA) | 10 | 30 | 50 | 100 | 200 | 500 | 800 | 1000 | |||
DC Input | Input voltage range | 40-850V The DC voltage range can be selected according to the power requirements; other voltages are available upon request. (850-1500V) | |||||||||
Bypass input | Allowable Input V Range | 380VAC±15%, other voltages available upon request | |||||||||
Input frequency range | 50/60Hz±5Hz, other frequencies available upon request | ||||||||||
Bypass transfer time | ≥200ms, customizable to <10ms | ||||||||||
Communication Output | Rated V & Freq | 380VAC 50/60Hz Other voltages/frequencies are available upon request. | |||||||||
Output V Accuracy | ±1% | ||||||||||
Output Freq Accuracy | ±0.1% | ||||||||||
Rated Current (A) | 15.2 | 45.6 | 76 | 152 | 303.9 | 760 | 1216 | 1520 | |||
The rated current is calculated based on an output voltage of AC380V. | |||||||||||
THD (Waveform Distortion Rate) | <3% (linear load) | ||||||||||
Dynamic Response Time | 2ms (load 0-100%) | ||||||||||
Overload Capacity | 110% for 10 minutes, 200% for 3 seconds, customizable up to 400% for 1 second | ||||||||||
CF (Crest Factor) | 3:1 | ||||||||||
Max Inverter Efficiency | 100% | ||||||||||
WorkingEnvironment | Insulation Strength (In/Out) | 1500VAC,1 minute | |||||||||
Noise (at 1meter) | ≤65dB(1 meter away) | ||||||||||
Operating Ambient Temp | -10℃ to -50℃ Other temperatures can be customized | ||||||||||
Humidity | 0-90%, non-condensing | ||||||||||
Operating altitude (m) | ≤6000m, derating required above 2000 meters (1% derating for every 100 meters increase in altitude) | ||||||||||
Indicator lights | Bypass, Inversion (or Operation, Fault) | ||||||||||
Display method | Touchscreen/LED digital display | ||||||||||
Protection functions | It features multiple protection functions, including input reverse connection protection, input over/undervoltage protection, output overload/overcurrent protection, three-phase voltage imbalance protection, drive protection, and overheating protection. | ||||||||||
Emergency shutdown | Equipped with an emergency stop button. | ||||||||||
Protection level | IP20 (customizable to IP54) | ||||||||||