Product Categories

IPS03-T2S05 IDEALPLUSING 5VDC 600mA Low Voltage Ac To DC Converter High Voltage AC-DC Converters For Medical Equipment
Model : IPS03-T2S05 5VDC 600mA High Voltage Power Supply Ac Dc Power Modules For Industrial Equipment ① Input : 85-264VAC /100-370 VDC ② Output : 5VDC 600mA ③ Max power: 3W ④ Size : 38.0* 19.5* 17.0(MM) ⑤ Industrial grade products, RoHS compliant We specialize in customizing AC-DC converters to meet your specific requirements. With customized input and output voltage and current, our offerings range from 1V to 1000V and 1A to 1000A. We provide both isolated and non-isolated converter design options. Please visit our website and submit any inquiries to explore our capabilities further. Our dedicated team endeavors to respond within one hour. Thank you for considering our services.

INTRODUCE

A  AC/DC high voltage input power supply is a device that converts a high voltage DC power supply into a DC power supply of a different voltage level. They are widely used in a variety of applications


FEATURES

lUltra-small size, save space

lInput and output isolation

lUniversal input voltage: 85-264VAC/100-370VDC

lOutput overcurrent protection, short circuit protection

lThis series of products are widely used in industry, power, instrumentation, communication, smart home and other fields


SPECIFICATIONS

Project

Condition

Minimum

Typical Value

Maximum

 

Input voltage range

AC input

85VAC

230VAC

264VAC

DC input

100VDC

310VDC

370VDC

 

Input Current

230VAC

/

/

40mA

115VAC

/

/

80mA

Output voltage accuracy

 


/

±5%

/

Other outputs

/

±2%

/

Linear regulation rate

Full load

/

±1%

/

Load regulation rate

10%-100% load

/

±1%

/

Output ripple and noise*

20MHz bandwidth (peak-to-peak)

5V/12V output

 

/

150mV

/

24V output


240mV


Short circuit protection


Can be short-circuited for a long time, self-recovery

Output overcurrent protection


≥110%Io, self-recovery

Minimum load


0

/

/

Power-off hold time


/

20ms

/

Operating temperature

IPS03-T2Sxx

-15

-

+70℃

IPS03-T2Sxx-LT

-40℃


+70℃

Storage temperature


-40℃

/

+105℃

Storage humidity


/

/

95%RH

Switching frequency


/

40kHz

/

Insulation voltage

Input to output, test 60s, ≤5mA

3000VAC

/

/

MTBF

MIL-HDBK-217F@25℃

215000h

/

/

Note: * Ripple and noise are tested using the parallel line test method (the oscilloscope probe is close to the test, and a 10μF high-frequency low-resistance electrolytic capacitor and a 0.1μF ceramic capacitor are connected in parallel at the close test point). If the user needs to reduce the output ripple, an LC filter circuit can be added. For specific parameters, see the recommended circuit (L2 and C1), which can be reduced to 50mV (TYP).


MODEL LIST

Model

Input voltage range

Output Power

Rated output voltage( V )

Rated output current( mA )

size

(Length * Width * Height)

IPS03-T2S05

 

 

 

85-264VAC/100-370VDC

 

 

 

 

 

 

 

 

 

3W

5VDC

600mA

38.0* 19.5* 17.0 mm

(Regular version)

IPS03-T2S12

12VDC

250mA

IPS03-T2S24

24VDC

125mA

IPS03-T2S05- LT

5VDC

600mA

IPS03-T2S12- LT

12VDC

250mA

IPS03-T2S24- LT

24VDC

125mA

IPS03-T2S05-S

 

 

 

3W

5VDC

600mA

38.0* 19.5* 17.0 mm

(Safety version)

IPS03-T2S12-S

12VDC

250mA

IPS03-T2S24-S

24VDC

125mA

IPS03-T2S05- SLT

5V

600mA

IPS03-T2S12- SLT

12V

250mA

Remark: The “ S ” suffix indicates the safety version, and the one without the “ S ” suffix indicates the normal version. " suffix indicates an ultra-low temperature version, with the lowest operating temperature being -40 °C.


WhatsApp
Wechat
Contact Us
Your Name:
Your Email:
Your Message:
This website uses cookies to enhance user experience and to analyze performance and traffic on our website.
We also share information about your use of our site with our social media, advertising and analytics partners.
Do Not Sell My Personal Information
Accept Cookies