IPS-LY-K-500K 500KVA Dual Power Source Sensing Automatic Emergency Command Center Power Fire Pump Controllers
①Model:IPS-LY-K-500K ②AC INPUT: 3-phase 3-wire/4-wire 380VAC±15% 50HZ or Customize ③DC INPUT: Sealed maintenance-free lead-acid battery (backup time 90min) ④AC OUTPUT: 3-phase 380VAC 50HZ (pure sine wave, switching time <3ms) ⑤Maximum equipment power: 550KVA ; Rated equipment power: 500KVA ⑥Application: Small fire-fighting equipment, low-power motor emergency power (or customized for different areas) ⑦Adjusting method: LCD display, switchable between Chinese and English, integrated display and control, and clear display of operating data ⑧Protection features include input reverse polarity/undervoltage protection, output overload/short circuit protection, and over-temperature protection.
Datasheet: Download

model

LY-D-0.5K------LY-D-20K

battery

Type

Sealed, maintenance-free lead-acid battery

Backup Time

90 minutes

Charging Time

Within 20 hours

Mains power input

Rated Voltage (V)

220V/380V

Voltage Range (V)

220/380±15%

Frequency Range (Hz)

50hz

Emergency output

Rated Voltage (V)

220Vac

Rated Frequency (Hz)

50Hz

Voltage Accuracy (V)

220V±3%

Frequency Accuracy (Hz)

50Hz±0.05Hz

(THD)

≤3% (linear load)

Dynamic Response (0~100% Load)

5%

Power Factor (PF)

0.8

Overload Capacity

150%,10 seconds

Peak Factor (CF)

3:1

Inverter Efficiency

90% (80% resistive load)

 

Working Env. Temp.

Withstand Voltage Requirement (Input/Output)

2000Vac,1 minute

Noise (1 meter)

≤50db

Operating Ambient Temp.

-10℃~~+50℃

Humidity

0~~90%,No condensation

Operating Altitude m

≤2000

Protection functions

Complete protection features include input reverse polarity and undervoltage protection, output overload and short-circuit protection, and over-temperature protection.

Other

It uses a power frequency isolation transformer, provides a pure sine wave output, is completely stable, and has strong load capacity.


model

LY-S-2.2K------LY-S-500K

battery

Type

Sealed, maintenance-free lead-acid battery

Backup Time

90 minutes

Charging Time

Within 20 hours

Mains power input

Rated Voltage (V)

380V

Voltage Range (V)

380±15%

Frequency Range (Hz)

50hz

Emergency output

Rated Voltage (V)

380VAC

Rated Frequency (Hz)

50Hz

Voltage Accuracy (V)

380V±3%

Frequency Accuracy (Hz)

50Hz±0.05Hz

(THD)

≤3% (linear load)

Dynamic Response (0~100% Load)

5%

Power Factor (PF)

0.8

Overload Capacity

150%,10 seconds

Peak Factor (CF)

3:1

Inverter Efficiency

90% (80% resistive load)

 

Working Env. Temp.

Withstand Voltage Requirement (Input/Output)

2000Vac,1 minute

Noise (1 meter)

≤50db

Operating Ambient Temp.

-10℃~~+50℃

Humidity

0~~90%,No condensation

Operating Altitude m

≤2000

Protection functions

Complete protection features include input reverse polarity and undervoltage protection, output overload and short-circuit protection, and over-temperature protection.

Other

It uses a power frequency isolation transformer, provides a pure sine wave output, is completely stable, and has strong load capacity.


model

LY-S-2.2K------LY-S-500K

battery

Type

Sealed, maintenance-free lead-acid battery

Backup Time

90 minutes

Charging Time

Within 20 hours

Mains power input

Rated Voltage (V)

380V

Voltage Range (V)

380±15%

Frequency Range (Hz)

50hz

Emergency output

Rated Voltage (V)

0-380V AC adjustable

Rated frequency (Hz)

0-50Hz (Variable frequency start-up and normal operation, frequency is adjustable)

(THD)

≤3% (linear load)

Dynamic Response (0~100% Load)

5%

Power Factor (PF)

0.8

Overload Capacity

150%,10 seconds

Peak Factor (CF)

3:1

Inverter Efficiency

90% (80% resistive load)

 

Working Env. Temp.

Withstand Voltage Requirement (Input/Output)

2000Vac,1 minute

Noise (1 meter)

≤50db

Operating Ambient Temp.

-10℃~~+50℃

Humidity

0~~90%,No condensation

Operating Altitude m

≤2000

Protection functions

Complete protection features include input reverse polarity and undervoltage protection, output overload and short-circuit protection, and over-temperature protection.

Other

It uses a power frequency isolation transformer, provides a pure sine wave output, is completely stable, and has strong load capacity.


model

LY-S-2.2K------LY-S-500K

battery

Type

Sealed, maintenance-free lead-acid battery

Backup Time

90 minutes

Charging Time

Within 20 hours

Mains power input

Rated Voltage (V)

380V

Voltage Range (V)

380±15%

Frequency Range (Hz)

50hz

Emergency output

Rated Voltage (V)

380VAC

Rated Frequency (Hz)

50Hz

(THD)

≤3% (linear load)

Dynamic Response (0~100% Load)

5%

Power Factor (PF)

0.8

Overload Capacity

150%,10 seconds

Peak Factor (CF)

3:1

Inverter Efficiency

90% (80% resistive load)

 

Working Env. Temp.

Withstand Voltage Requirement (Input/Output)

2000Vac,1 minute

Noise (1 meter)

≤50db

Operating Ambient Temp.

-10℃~~+50℃

Humidity

0~~90%,No condensation

Operating Altitude m

≤2000

Protection functions

Complete protection features include input reverse polarity and undervoltage protection, output overload and short-circuit protection, and over-temperature protection.

Other

It uses a power frequency isolation transformer, provides a pure sine wave output, is completely stable, and has strong load capacity.


model

LUG-S-

10K

30K

 50K

75K

100K

DC input

Rated Voltage V

384

Voltage Range V

300—480

AC input

Rated Voltage V

380V

Voltage Range V

380±15%

Frequency Range Hz

45—65

Power Factor PF

0.8

Switching time

Bypass↔Inverter ms

≤4

Mains↔DC Panel ms

0

 

 

AC output

Rated Capacity KVA

10

30

50

75

100

Rated Voltage V

380VAC

Rated Frequency Hz

50Hz

Voltage Accuracy V

380V±3%

Frequency Accuracy Hz

50Hz±0.05Hz

THD

≤3%(Linear load)

Dynamic Response Load 0~100%

5%

Power Factor (PF)

0.8

Overload Capacity

150%,10 seconds

Crest Factor CF

3:1

Inverter Efficiency

90%(80% resistive load)

 

Working Env. Temp.

Withstand Voltage Requirements (Input/Output)

2000Vac,1 minute

Noise (1 meter)

≤50db

Operating Ambient Temp.

-10℃~~+50℃

Humidity

0~~90%,No condensation

Operating Altitude m

≤2000

Protection functions

Complete protection features include input reverse polarity and undervoltage protection, output overload and short-circuit protection, and over-temperature protection.

Other

It uses a power frequency isolation transformer, provides a pure sine wave output, is completely stable, and has a strong load capacity.



WhatsApp
Wechat
Contact Us
Your Name:
Your Email:
Your Message:
This website uses cookies to enhance user experience and to analyze performance and traffic on our website.
We also share information about your use of our site with our social media, advertising and analytics partners.
Do Not Sell My Personal Information
Accept Cookies