Specifications | 600V output series | ||||
Model | IPS-DH10-6001 | IPS-DH10-6002 | IPS-DH10-6003 | IPS-DH10-6004 | IPS-DH10-6005 |
AC input | Single-phase 220V ±10% | ||||
Frequency 50Hz/60Hz | |||||
Output voltage | 0-600V | ||||
Output current | 0-1A | 0-2A | 0-3A | 0-4A | 0-5A |
Output power | 600W | 1200W | 1800W | 2400W | 3000W |
Power stability | ≦ 0.1%+10mV | ||||
Load stability | ≦ 0.1%+30mV | ||||
Voltage regulation accuracy | ≦ ±0.1%FS | ||||
Steady flow accuracy | ≦ ±0.1%FS | ||||
Ripple (rms) | ≤ 0.1%FS+10mV | ||||
Voltage setting accuracy | ±0.1%FS+10mV | ||||
Current setting accuracy | ±0.1%FS+10mA | ||||
Voltage readback accuracy resolution | 5-digit display meter Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||||
10mV | |||||
Current readback accuracy resolution | 5-digit display meter Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||||
0.1mA | |||||
Display method | Segmented display monitor | ||||
Output overvoltage protec- tion | The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. | ||||
Output overcurrent protection | The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. | ||||
Over-temperature protection | Built-in OTP (Over-Temperature Protection), with a protection value of 85℃ ± 5% (heatsink temperature). | ||||
Voltage setting | Menu settings, encoder knob input | ||||
Current setting | Menu settings, encoder knob input | ||||
Communication methods | RS-485/RS-232 (supports Modbus and SCPI protocols) | ||||
Function | Constant voltage/current operation, foldback current protection, memory mode, LIST sequence cycling, adjustable ON/OFF time, pulse width output, 9999 cycles, three sets of preset voltage and current (full-width models), key lock. | ||||
Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||||
Heat dissipation method | Forced air cooling | ||||
Operating environment | Designed for indoor use; operating temperature: 0℃ to 40℃ ; humidity: 10% to 85% RH. | ||||
Storage environment | Temperature: -20℃ to 70℃ ; Humidity: 10% to 90% RH | ||||
Size and weight | W215*H44*L450 (mm),Approximately 2.8 kg | W430*H44*L450 (mm),Approximately 3.5 kg | |||
Note: All values are typical values, and may be exceeded under different load or other conditions. Accuracy is measured with voltage sensing at the load end. Actual values may deviate from rated values due to temperature variations and component aging. | |||||
Note: FS stands for full scale. The three characters indicate that the last digit of the display fluctuates by three digits. | |||||