Product Categories

IPS-DH10-6004 2400W High-Accuracy Programmable DC Power Power Fintech Startup Laboratory Power
①Model: IPS-DH10-6004 ②AC INPUT: 1-phase 2-wire 220VAC±10% 50/60HZ or Customize ③DC OUTPUT:  0-600VDC 0-4A (pure DC, ripple ≤0.1%FS+10mV) ④Output Power: 2400W ⑤Max Maximum equipment power: 2640W ; Rated equipment power: 2400W ⑥Application:Ultra-high voltage medium-current testing, precision electronics R&D (or customized for different areas) ⑦Adjusting method: 5-digit segmented display, switchable between Chinese and English, encoder knob input, clear operating data ⑧Single unit outer carton dimensions: 53×49×12 CM ⑨Net weight/Gross weight: 8.5KG/9.5KG Additional features: Constant voltage/constant current mode, 30-step programmable sequence, supports Mod bus/SCPI communication protocols Protection features include over voltage protection, over current protection, over-temperature protection, and fold back current protection.
Datasheet: Download

Specifications

600V output series

Model

IPS-DH10-6001

IPS-DH10-6002

IPS-DH10-6003

IPS-DH10-6004

IPS-DH10-6005

 

AC input

Single-phase 220V ±10%

Frequency 50Hz/60Hz

Output voltage

0-600V

Output current

0-1A

0-2A

0-3A

0-4A

0-5A

Output power

600W

1200W

1800W

2400W

3000W

Power stability

≦ 0.1%+10mV

Load stability

≦ 0.1%+30mV

Voltage regulation accuracy

≦ ±0.1%FS

Steady flow

accuracy

≦ ±0.1%FS

Ripple (rms)

≤ 0.1%FS+10mV

Voltage setting

accuracy

±0.1%FS+10mV

Current setting

accuracy

±0.1%FS+10mA

 

Voltage readback

accuracy resolution

5-digit display meter  Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)

10mV

 

Current readback

accuracy resolution

5-digit display meter  Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)

0.1mA

Display method

Segmented display monitor

Output overvoltage protec-

tion

The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable.

The output will be shut off after protection is triggered.

Output overcurrent

protection

The menu allows you to set O.I.P. protection, with the protection value being freely adjustable.

After protection is triggered, the output will be shut off.

Over-temperature

protection

Built-in OTP (Over-Temperature Protection), with a protection value of 85℃ ± 5% (heatsink temperature).

Voltage setting

Menu settings, encoder knob input

Current setting

Menu settings, encoder knob input

Communication

methods

RS-485/RS-232 (supports Modbus and SCPI protocols)

Function

Constant voltage/current operation, foldback current protection, memory mode, LIST sequence cycling, adjustable ON/OFF time, pulse width

output, 9999 cycles, three sets of preset voltage and current (full-width models), key lock.

Output polarity

The positive (+) and negative (-) outputs can be grounded arbitrarily.

Heat dissipation

method

Forced air cooling

Operating

environment

Designed for indoor use; operating temperature: 0℃ to 40℃ ; humidity: 10% to 85% RH.

Storage

environment

Temperature: -20℃ to 70℃ ; Humidity: 10% to 90% RH

Size and weight

W215*H44*L450 (mm),Approximately 2.8 kg

W430*H44*L450 (mm),Approximately 3.5 kg

Note: All values are typical values, and may be exceeded under different load or other conditions. Accuracy is measured with voltage sensing at the load end.  Actual values

may deviate from rated values due to temperature variations and component aging.

Note: FS stands for full scale.  The three characters indicate that the last digit of the display fluctuates by three digits.


WhatsApp
Wechat
Contact Us
Your Name:
Your Email:
Your Message:
This website uses cookies to enhance user experience and to analyze performance and traffic on our website.
We also share information about your use of our site with our social media, advertising and analytics partners.
Do Not Sell My Personal Information
Accept Cookies