FUNCTION DESCRIPTION
1 | Our company's power supply features a full protection function, large starting power, wide application range, durability, high reliability, large power margin of built-in components! |
2 | Main materials: 105-degree capacitor. Imported parts are used for main chips and power tubes. FR-4 double-sided 2 oz high-quality plate is used for the circuit board to ensure no faulty soldering |
3 | Undervoltage protection: input Undervoltage protection is mainly used when the battery power supply can effectively prevent the over-discharge of the battery, so as to protect the battery and prolong the service life of the battery. |
4 | Overvoltage protection: overvoltage protection starts to prohibit output, so as to protect the power tube and prevent overpressure operation. |
5 | Overload protection: the output defaults to constant voltage output (hiccup protection. After overload, when the load is restored, it will automatically resume work). |
6 | Output mode: the default is constant voltage output. If charging, etc., or power supply is used in parallel, please select constant current mode. In this mode, it can also be used as a charger (three-stage charging). |
7 | Temperature protection: start intelligent ventilation and heat dissipation at 50 degrees inside the machine. When the power tube is 90 degrees, start the temperature protection and prohibit the output. |
8 | Input range: ±15% of the rated voltage. The actual startup protection manufacturer considers that a certain margin is about ±18% of the rated voltage. After startup, it is forbidden to output. |
9 | Wiring terminal: when the low-voltage 12V and 24V input current is relatively large, the input wiring terminal is connected in parallel to increase the current capacity of the terminal. |
10 | Voltage stabilizing range: the input voltage is lower than 10% of the rated voltage, the output is not regulated, and the input high point can be regulated. |
11 | Isolated output: the input and output are isolated, which is suitable for isolating input and output interference signals with any valuable precision instruments and other loads! |
12 | Operating temperature: according to the feedback of many customers in the north, the northern low temperature of - 30 to - 40 degrees can operate well without abnormality! When operating in a high-temperature environment, reduce the load rate as appropriate. |
13 | Soft start: the factory default soft-start time is 2-3s. |
14 | The positive and negative poles shall not be connected wrongly: the power supply with input voltage less than 60V is not equipped with reverse connection protection. Do not connect wrongly in use! If it is connected incorrectly, the fuse will be burnt out slightly, and the power tube will be burnt out seriously. Another 100V Most of the above input power supplies are equipped with anti-reverse connection protection. |
SPECIFICATION
Brand | IDEALPLUSING |
Model | IPS-DTD64S280-2.14 |
Rate Input Voltage | 64VDC |
Range Input Voltage | 64VDC±15% |
Output voltage | 280VDC±2% |
Output current | 2.14A |
Loading rate | It is recommended that the general load continuous work control at about 80%, power motor class inductive, capacitive, amplifier, radio and other loads with a load of about 40-50% is better |
Working time | 24*7(80% Load) |
Over load and current | 110~150% |
Low voltage protection | Start-up below -18% of rated input voltage |
Over voltage protection | Rated input voltage +18% or more to start |
Empty Load Loss | <3W |
Empty current | <0.2A |
Over load protection | 105%~135% |
Start up time | 1~2S |
Seismic resistance | 10~500Hz,2G 10sec/1cycle, total 60min, each axis |
Pressure resistance | Between input and output: 1.5KVAC, input and enclosure: 1.5KVAC output and enclosure: 0.5KVAC |
Isolation situation | Input and output isolation status. |
Isolation resistors | Between input and output, input to enclosure, output to enclosure: 500VDC/100M Ohms |
Working temperature/humidity | -30℃~+65℃,20%~90%RH |
Storage temperature / humidity | -40℃~+85℃,10%~95%%RH |
Dimension | Base on model |
Housing material | Aluminum |
Net weight/Gross weight | Base on model |
MODEL LIST
Item | DC Input Voltage (Choose 1 Voltage) | DC Output Voltage | Peak Power (Choose 1 Power) | Continuous Power | Efficiency |
#1 | 12V±15% 24V±15% 36V±15% 48V±15% 60V±15% 72V±15% 90V±15% 100V±15% 110V±15% 120V±15% 130V±15% 150V±15% 200V±15% 220V±15% 250V±15% 280V±15% 300V±15% 310V±15% 400V±15% 450V±15% 500V±15% 550V±15% 600V±15% 650V±15% 700V±15% 110VAC±15% 220VAC±15% 380VAC±15% | 12V±1-2% | 100W 200W 300W 400W 500W 600W 750W 1000W 2000W 3000W 4000W 5000W 6000W 7500W 8000W | Peak Power*80% | 90±4% |
#2 | 24V±1-2% | Peak Power*80% | 90±4% | ||
#3 | 36V±1-2% | Peak Power*80% | 90±4% | ||
#4 | 48V±1-2% | Peak Power*80% | 90±4% | ||
#5 | 60V±1-2% | Peak Power*80% | 90±4% | ||
#6 | 72V±1-2% | Peak Power*80% | 90±4% | ||
#7 | 80V±1-2% | Peak Power*80% | 90±4% | ||
#8 | 100V±1-2% | Peak Power*80% | 90±4% | ||
#9 | 110V±1-2% | Peak Power*80% | 90±4% | ||
#10 | 150V±1-2% | Peak Power*80% | 90±4% | ||
#11 | 200V±1-2% | Peak Power*80% | 90±4% | ||
#12 | 220V±1-2% | Peak Power*80% | 90±4% | ||
#13 | 250V±1-2% | Peak Power*80% | 90±4% | ||
#14 | 280V±1-2% | Peak Power*80% | 90±4% | ||
#15 | 300V±1-2% | Peak Power*80% | 90±4% | ||
#16 | 310V±1-2% | Peak Power*80% | 90±4% | ||
#17 | 350V±1-2% | Peak Power*80% | 90±4% | ||
#18 | 400V±1-2% | Peak Power*80% | 90±4% | ||
#19 | 450V±1-2% | Peak Power*80% | 90±4% | ||
#20 | 500V±1-2% | Peak Power*80% | 90±4% | ||
#21 | 550V±1-2% | Peak Power*80% | 90±4% | ||
#22 | 600V±1-2% | Peak Power*80% | 90±4% | ||
#23 | 650V±1-2% | Peak Power*80% | 90±4% | ||
#24 | 700V±1-2% | Peak Power*80% | 90±4% | ||
#25 | 800V±1-2% | Peak Power*80% | 90±4% | ||
#26 | 1000V±1-2% | Peak Power*80% | 90±4% |