IPS-GPU-60KVA IDEALPLUSING 60KVA 3-Phase 400Hz Frequency Mobile Aircraft Static Ground Power Supply Ac Power Supply
① AC INPUT voltage: Single phase 110/220VAC±15% or 3-phase 380/450VAC±15% ② AC INPUT frequency: 50/60hz or 400hz optional ③ AC OUTPUT voltage: Single phase 110/220VAC±15% or 3-phase 380/450VAC±15% ④ AC OUTPUT frequency: 50/60hz or 400hz optional ⑤ Output capacity: 60KVA ⑥ Power factor: 0.8 ⑦ Machine size: 3400*1500*1500(MM) ⑧ Net Weight: 2 Tons ⑨ Protection:Overload, over-current, overheating (85p ± 5p), short circuit, over-voltage ⑩ OEM :customized specifications acceptable We specialize in customizing diesel trailer power supplies to meet your specific requirements. With customized input and output voltages and currents, our products range from 1V to 1000V and 1A to 1000A. We provide one-to-one customization services. You tell us your needs and we will recommend the best solution for you

WHO WE ARE?

We have own factories (locate in shenzhen China), and more than 20 cooperationed factories, more than 60 workers and 10000 different models with specification of power supply.

It is one of suppliers on integrating , developing, manufacture , sales,engineering design and construction for different kind of power supply.

We strict implement the operation guideline of  “Leading Technology, Reliable Quality, Satisfactory Service & Customers First ! ”.


WHAT WE DO?

We supply reliable and innovative Ground Power Units.

Looking for a reliable and innovative Ground Power Unit to supply your aircraft?  

No matter which type of Ground Power Unit you are looking for, we have the power to cover your needs.

We have a full range of solid-state, diesel-driven, and battery-powered Ground Power Units from 400 Hz frequency converters to 28 VDC /270 VDC Ground Power Unit or a combination.

Whether you require a power supply for hangar use, for use at aircraft parking positions, or in remote areas,  we have the right solution.  


We got you covered!

  •  DC-DC converter (Isolated and non-isolated), voltage from 12vdc to 1000vdc, power from 1-200kw. 

  •  AC DC power supply, voltage from 0 to 200kv, current from 0-20k amps. 

  •  DC AC inverter, dc voltage from 12vdc to 2000vdc, and power from 100w to 500kw. 

  • AC AC power source, single phase or 3 phases, 10-500hz, power supply from 1kva to 500kva.

  •  AC DC Ground Power Unit, from 300 amps to 50000 amps.


SPECIFICATION

Brand                              IDEALPLUSING

Model

IPS-GPU-60KVA

1.Product features

The IPS-GPU-60KVA power supply vehicle is a trailer-type AC power supply vehicle. It uses a diesel engine as the prime mover to drive a generator to generate

medium-frequency power. If DC is required, it can be generated through an external commutator. The entire generator set and electrical control system are loaded on the trailer chassis. The vehicle's AC and DC power supplies can be output independently.

2.Main uses and scope of application

When supporting aircraft that use 115/200V 400Hz electricity, in 115V mode, it can output AC 115/200V for power-on and starting, and can provide AC 220V50HZ detection power.

3.Use environment and   working conditions

 

Altitude: 4000m

Ambient temperature: (-20+50)℃ , Relative humidity: not more than 95 (25℃)

4.Impact on the environment and safety requirements

The diesel engine and generator of the vehicle are nationally approved products, and the emission meets environmental protection requirements. There are no special safety requirements for operating this vehicle, which can ensure the safety of the operator.

 

5.Performance data

Capacity: 60 KVA.

Rated current: 175A.

Power factor: 0.8.

Rated voltage: 115V/200V.

Rated frequency: 400Hz.

Unit Configuration Table

2-1

Name

Configuration

Remark

Engine

Weichai


Dynamo

 

Self-developed


Couplings

 

Elastic connection disc


Cooling water tank

Dedicated water tank


Control system

Intelligent four protections


Battery float charge

Included


Connection base (common base)

I-beam or channel steel


Battery

Maintenance-free battery × 2


Battery cable

Included


Diesel filter

Equipped on the unit

Original

Oil filter

 

Equipped on the unit

Original

Shock absorber (pad)

Between the unit and the base


Output circuit breaker

Included


Connecting oil pipe

Included


Operation, Installation, Parts manuals

Included


Connecting flange

Included


Factory test and commissioning of the unit

Included


Engine oil, Antifreeze

Included


Diesel engine information

Included


Generator Information

Included


Certificate

Included


PE film packaging

Included


Remote technical guidance

After-sales service at any time


2-2

 

 

Alarm

▶Start and stop failure

▶Charging failure

▶Overcurrent

▶The unit voltage is too low/too high ▶Oil pressure too low

▶Emergency stop

▶Engine temperature is too high ▶Overload

 

 

 

Display

▶Unit voltage (phase-phase/phase-line)

▶Engine oil pressure (psi-bar)

▶Unit current (L1, L2, L3)

▶Engine temperature (°C and ° F) ▶Unit frequency (Hz)

▶Factory battery voltage

▶Engine running hour meter

▶Unit kVA, kWh

▶The percentage of unit power to rated power ▶Unit Cos (σ)

2-3

Output


1-way AC: 115V/200V; meets the power-on inspection and start-up requirements of civil aircraft, military aircraft, and helicopters.

Current

AC Current

Capacity

60KVA

Phase

Three-phase

Voltage

115V/200VAC

 

Voltage adjustable

90~138VAC    Phase voltage: 90~138VAC

Frequency

400Hz

Frequency stability

0.5%

Voltage regulation rate

< ±1%

Load stability

< ±1%

Waveform distortion

≤2%    Sine wave ≤2%

Reaction time

 100ms


Panel display

Frequency Voltage Current

Voltage Current

Adapt to load

No type restriction, non-linear loads such as capacitive and inductive loads can be used with derating

Protective devices

 

Electronic circuits quickly detect overvoltage, overcurrent, overload, overtemperature and short circuit, automatically trip protection and alarm.

Cooling device


Usage Environment


Operating   temperature

-20~50℃

Relative humidity

 

0-90% (non-condensing state)

Altitude

≤4000 m

Structure

Self-propelled

2-4

III.Unit Configuration Details

Name

Model

Unit

Remark

Engine

Huai Chai

Tower

Installation

Dynamo

Self-developed

Tower

Installation

Cooling water tank

Original water tank

Set

Installation

Output circuit breaker

Contains

Indivual

 

Installation

Control system

Four protection control system

Set

Installation

Chassis

Standard chassis

Set

Installation

Diesel filter

Original


 

Installation

Oil filter

Original


Installation

Air filter

Original


Installation

Battery

Maintenance-free battery

Set

Scattered

Battery cable

Pure copper battery wire


Contains

Muffler

Contains


Contains

Shock absorbers

Original


Installation

Silent box

Equipped with 60KVA unit

Set

Contains

Output aircraft docking cable

115V/200V400HZ aircraft special cable

Set

 

Installation

Size mm

3400*1500*1500


Chassis can be customized

Net Weight

2 Tons




WhatsApp
Wechat
Contact Us
Your Name:
Your Email:
Your Message:
This website uses cookies to enhance user experience and to analyze performance and traffic on our website.
We also share information about your use of our site with our social media, advertising and analytics partners.
Do Not Sell My Personal Information
Accept Cookies