Product Categories

IPS-LZ33-60K-MF 60KVA Medium Frequency Surface Treatment Power Supply Frequency Response Characteristic Customization Full Lifecycle Service
①Model: IPS-LZ33-60K-MF ②AC INPUT: 3-phase 3-wire / 3-phase 4-wire 380VAC±10% 50/60HZ±10% or Customize ③AC OUTPUT: 3-phase 4-wire 115V/200VAC (0-150V/0-260V adjustable) 400HZ (300-500HZ adjustable) ④Maximum equipment power: 66KVA ; Rated equipment power: 60KVA ⑤Application: Three-phase airborne equipment testing, military radar main power (or customized for different areas) ⑥Adjusting method: High-precision four-digit digital LED display, clear operating data, multi-turn potentiometer precise adjustment ⑦ IGBT/PWM pulse width modulation, pure sine wave output, frequency stability ≤0.1%, insulation resistance ≥10MΩ ⑧Protection features include overvoltage protection, overcurrent protection, short circuit protection, and overheating protection with alarm.
Datasheet: Preview

Power supply model

LZ11-0.5K

LZ11-1K

LZ11-3K

LZ11-5K

LZ11-10K

Rated capacity

500VA

1KVA

3KVA

5KVA

10KVA

Circuit diagram

IGBT/PWM Pulse Width Modulation Method

Enter

Ph.Num

1- Phase

Volt

220V±10%

Freq

50Hz/60Hz±10%

Output

Ph.Num

1- Phase

Wfm

Pure Sine Wave

Rated Volt

115V

Adj.Range

0-150VContinuously Adjustable

Load Reg.Rate

≤1%

Rated Freq

400Hz

Adj.Range

300Hz-500Hz Continuously Adjustable (Custom frequencies available)

Freq.Stab

Rated Frequency ≤0.1%; Adjustment Range ≤0.01%

Wfm.Dist (THD)

THD≤3%

Eff

≥80%(100%Load)

Resp.Time

≤2ms

Suit.Load

No load type restrictions, but motors and rectifying loads require derating.

Display

High-precision four-digit digital LED display for voltage, current, frequency, power, and power factor

Cooling method

Fan Cooling

Noise level

≤55dB

Output protection

Complete protection functions and alarm devices for overvoltage, overcurrent, short circuit, and overheating.

Reliability

MTBF

1.0×105h

MTTR

0.5h

Env

Work.Temp

-25℃-55℃

Rel.Hum

0-90% (non-condensing)

Altitude

≤2000 meters


Power supply model

LZ31-15K

LZ31-20K

LZ31-30K

LZ31-60K

LZ31-100K

Rated capacity

15KVA

20KVA

30KVA

60KVA

100KVA

Circuit diagram

IGBT/PWM Pulse Width Modulation Method

Enter

Ph.Num

3- Phase

Volt

380V±10%

Freq

50Hz/60Hz±10%

Output

Ph.Num

1- Phase

Wfm

Pure Sine Wave

Rated Volt

115V

Adj.Range

0-150VContinuously Adjustable

Load Reg.Rate

≤1%

Rated Freq

400Hz

Adj.Range

300Hz-500Hz Continuously Adjustable (Custom frequencies available)

Freq.Stab

Rated Frequency ≤0.1%; Adjustment Range ≤0.01%

Wfm.Dist (THD)

THD≤3%

Eff

≥80%(100%Load)

Resp.Time

≤2ms

Suit.Load

No load type restrictions, but motors and rectifying loads require derating.

Display

High-precision four-digit digital LED display for voltage, current, frequency, power, and power factor

Cooling method

Fan Cooling

Noise level

≤55dB

Output protection

Complete protection functions and alarm devices for overvoltage, overcurrent, short circuit, and overheating.

Reliability

MTBF

1.0×105h

MTTR

0.5h

Env

Work.Temp

-25℃-55℃

Rel.Hum

0-90% (non-condensing)

Altitude

≤2000 meters


Power supply model

LZ13-0.5K

LZ13-1K

LZ13-3K

LZ13-5K

LZ13-10K

Rated capacity

0.5VA

1VA

3VA

5VA

10VA

Circuit diagram

IGBT/PWM Pulse Width Modulation Method

Enter

Ph.Num

1- Phase

Volt

220V±10%

Freq

50Hz/60Hz±10%

Output

Ph.Num

1- Phase

Wfm

Pure Sine Wave

Phase voltage

Rated 115V; adjustable range 0-150V (continuously variable)

Line voltage

Rated 200V; adjustable range 0-260V (continuously variable)

Load Reg.Rate

≤1%

Rated Freq

400Hz

Adj.Range

300Hz-500Hz Continuously Adjustable (Custom frequencies available)

Freq.Stab

Rated Frequency ≤0.1%; Adjustment Range ≤0.01%

Wfm.Dist (THD)

THD≤3%

Eff

≥80%(100%Load)

Resp.Time

≤2ms

Suit.Load

No load type restrictions, but motors and rectifying loads require derating.

Display

High-precision four-digit digital LED display for voltage, current, frequency, power, and power factor

Cooling method

Fan Cooling

Noise level

≤55dB

Output protection

Complete protection functions and alarm devices for overvoltage, overcurrent, short circuit, and overheating.

Reliability

MTBF

1.0×105h

MTTR

0.5h

Env

Work.Temp

-25℃-55℃

Rel.Hum

0-90% (non-condensing)

Altitude

≤2000 meters


Power supply model

LZ33-15K

LZ33-20K

LZ33-30K

LZ3-45K

LZ33-60K

LZ33-100K

Rated capacity

15KVA

20KVA

30KVA

45KVA

60KVA

100KVA

Circuit diagram

IGBT/PWM Pulse Width Modulation Method

Enter

Ph.Num

3- Phase

Volt

380V±10%

Freq

50Hz/60Hz±10%

Output

Ph.Num

3-phase 4-wire

Wfm

Pure Sine Wave

Phase voltage

Rated 115V; adjustable range 0-150V (continuously variable)

Line voltage

Rated 200V; adjustable range 0-260V (continuously variable)

Load Reg.Rate

≤1%

Rated Freq

400Hz

Adj.Range

300Hz-500Hz Continuously Adjustable (Custom frequencies available)

Freq.Stab

Rated Frequency ≤0.1%; Adjustment Range ≤0.01%

Wfm.Dist (THD)

THD≤3%

Eff

≥80%(100%Load)

Resp.Time

≤2ms

Suit.Load

No load type restrictions, but motors and rectifying loads require derating.

Display

High-precision four-digit digital LED display for voltage, current, frequency, power, and power factor

Cooling method

Fan Cooling

Noise level

≤55dB

Output protection

Complete protection functions and alarm devices for overvoltage, overcurrent, short circuit, and overheating.

Reliability

MTBF

1.0×105h

MTTR

0.5h

Env

Work.Temp

-25℃-55℃

Rel.Hum

0-90% (non-condensing)

Altitude

≤2000 meters