Specifications | 50V output series | |||||
Model | IPS-DH10-5015 | IPS-DH10-5020 | IPS-DH10-5030 | IPS-DH10-5040 | IPS-DH10-5050 | IPS-DH10-5060 |
AC input | Single-phase 220V±10% | |||||
Frequency 50Hz/60Hz | ||||||
Output voltage | 0-50V | |||||
Output current | 0-15A | 0-20A | 0-30A | 0-40A | 0-50A | 0-60A |
Output power | 750W | 1000W | 1500W | 2000W | 2500W | 3000W |
Power stability | ≦ 0.1%+10mV | |||||
Load stability | ≦ 0.1%+30mV | |||||
Voltage regulation accuracy | ≦ ±0.1%FS | |||||
Steady flow accuracy | ≦ ±0.1%FS | |||||
Ripple (rms) | ≤ 0.1%FS+10mV | |||||
Voltage setting accuracy | ±0.1%FS+10mV | |||||
Current setting accuracy | ±0.1%FS+10mA | |||||
Voltage readback accuracy resolution | 5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||||
1mV | ||||||
Current readback accuracy resolution | 5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||||
1mA | ||||||
Display method | Broken code screen display | |||||
Output overvoltage protection | The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | |||||
Output overcurrent protection | The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | |||||
Over-temperature protection | Built-in OTP protection, with a protection value of 85℃ ±5% (radiator temperature). | |||||
Voltage setting | Menu settings, encoder knob input | |||||
Current setting | Menu settings, encoder knob input | |||||
Communication methods | RS-485/RS-232 (supports Modbus and SCPI protocols) | |||||
Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | |||||
Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||||
Heat dissipation method | Forced air cooling | |||||
Operating environment | Designed for indoor use, with a temperature range of 0℃ to 40℃ and a humidity range of 10% to 85% RH. | |||||
Storage environment | Temperature: -20℃~ 70℃ ; Humidity: 10% ~ 90% RH | |||||
Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | W430*H44*L450 (mm) Approximately 3.5 kg | ||||
Note: All values are typ | ical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||||
Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||||