IPS-LUD-D-10K 10KVA Low-Frequency UPS System Modular UPS Power Parallel Expansion Capability Overload Capacity
①Model: IPS-LUD-D-10K ②AC INPUT: 1-phase 2-wire 220V/380VAC±15% 45~65HZ or Customize ③DC INPUT: 220VDC (180-300VDC adjustable) ④AC OUTPUT: 1-phase 220VAC 50HZ (pure sine wave) ⑤Maximum equipment power: 11KVA ; Rated equipment power: 10KVA ⑥Application: Power plant telecontrol systems, small RTU/DCS equipment (or customized for different areas) ⑦Adjusting method: Large-screen LCD Chinese/English interface, integrated display and control, and clear display of operating data ⑧Protection features include input reverse polarity/undervoltage protection, output overload/short circuit protection, and over-temperature protection.
Datasheet: Download

model

LUD-D-

 1K

 10K

 30K

 45K

 60K

DC input

Rated Voltage V

220

Voltage Range V

180—300

AC input

Rated Voltage V

220V/380V

Voltage Range V

220/380±15%

Frequency Range Hz

45—65

Power Factor PF

0.9

Bypass input

Input Voltage Range

220±15%VAC

Input Rated Current A

4.5

45

136

202.5

272

Switching time

Bypass↔Inverter ms

≤4

Mains↔DC Panel ms

0

 

 

AC output

Rated Capacity KVA

1

10

30

45

60

Rated Voltage V

220Vac

Rated Frequency Hz

50Hz

Rated Current A

4.5

45

136

202.5

272

Voltage Accuracy V

220V±3%

Frequency Accuracy Hz

50Hz±0.05Hz

THD

≤3%(Linear load)

Dynamic Response Load 0~100%

5%

Power Factor (PF)

0.8

Overload Capacity

150%,10 seconds

Crest Factor CF

31

Inverter Efficiency

90%(80% resistive load)

 

Working Env. Temp.

Withstand Voltage Requirements (Input/Output)

2000Vac,1 minute

Noise (1 meter)

≤50db

Operating Ambient Temp.

-10℃~~+50℃

Humidity

0~~90%,No condensation

Operating Altitude m

≤2000

Protection functions

Complete protection features include input reverse polarity and undervoltage protection, output overload and short-circuit protection, and over-temperature protection.

Other

It uses a power frequency isolation transformer, provides a pure sine wave output, is completely stable, and has a strong load capacity.


model

LUD-D-

 5K

 10K

 50K

 100K

 200K

DC input

Rated Voltage V

220

Voltage Range V

180—300

AC input

Rated Voltage V

220V/380V

Voltage Range V

220/380±15%

Frequency Range Hz

45—65

Power Factor PF

0.9

Bypass input

Input Voltage Range

380±15%VAC

Input Rated Current A

7.6

15.2

76

152

304

Switching time

Bypass↔Inverter ms

≤4

Mains↔DC Panel ms

0

 

 

AC output

Rated Capacity KVA

5

10

15

30

45

Rated Voltage V

380Vac (3-phase 4-wire)

Rated Frequency Hz

50Hz

Rated Current A

7.6

15.2

76

152

304

Voltage Accuracy V

380V±3%

Frequency Accuracy Hz

50Hz±0.05Hz

THD

≤3%(Linear load)

Dynamic Response Load 0~100%

5%

Power Factor (PF)

0.8

Overload Capacity

150%,10 seconds

Crest Factor CF

31

Inverter Efficiency

90%(80% resistive load)

 

Working Env. Temp.

Withstand Voltage Requirements (Input/Output)

2000Vac,1 minute

Noise (1 meter)

≤50db

Operating Ambient Temp.

-10℃~~+50℃

Humidity

0~~90%,No condensation

Operating Altitude m

≤2000

Protection functions

Complete protection features include input reverse polarity and undervoltage protection, output overload and short-circuit protection, and over-temperature protection.

Other

It uses a power frequency isolation transformer, provides a pure sine wave output, is completely stable, and has a strong load capacity.


model

LUG-D-

6K

 10K

 30K

75K

100K

DC input

Rated Voltage V

384

Voltage Range V

300—480

AC input

Rated Voltage V

220V/380V

Voltage Range V

220/380±15%

Frequency Range Hz

45—65

Power Factor PF

0.8

Switching time

Bypass↔Inverter ms

≤4

Mains↔DC Panel ms

0

 

 

AC output

Rated Capacity KVA

6

10

30

75

100

Rated Voltage V

200VAC

Rated Frequency Hz

50Hz

Voltage Accuracy V

220V±3%

Frequency Accuracy Hz

50Hz±0.05Hz

THD

≤3%(Linear load)

Dynamic Response Load 0~100%

5%

Power Factor (PF)

0.8

Overload Capacity

150%,10 seconds

Crest Factor CF

31

Inverter Efficiency

90%(80% resistive load)

 

Working Env. Temp.

Withstand Voltage Requirements (Input/Output)

2000Vac,1 minute

Noise (1 meter)

≤50db

Operating Ambient Temp.

-10℃~~+50℃

Humidity

0~~90%,No condensation

Operating Altitude m

≤2000

Protection functions

Complete protection features include input reverse polarity and undervoltage protection, output overload and short-circuit protection, and over-temperature protection.

Other

It uses a power frequency isolation transformer, provides a pure sine wave output, is completely stable, and has a strong load capacity.


model

LUG-S-

10K

30K

 50K

75K

100K

DC input

Rated Voltage V

384

Voltage Range V

300—480

AC input

Rated Voltage V

380V

Voltage Range V

380±15%

Frequency Range Hz

45—65

Power Factor PF

0.8

Switching time

Bypass↔Inverter ms

≤4

Mains↔DC Panel ms

0

 

 

AC output

Rated Capacity KVA

10

30

50

75

100

Rated Voltage V

380VAC

Rated Frequency Hz

50Hz

Voltage Accuracy V

380V±3%

Frequency Accuracy Hz

50Hz±0.05Hz

THD

≤3%(Linear load)

Dynamic Response Load 0~100%

5%

Power Factor (PF)

0.8

Overload Capacity

150%,10 seconds

Crest Factor CF

31

Inverter Efficiency

90%(80% resistive load)

 

Working Env. Temp.

Withstand Voltage Requirements (Input/Output)

2000Vac,1 minute

Noise (1 meter)

≤50db

Operating Ambient Temp.

-10℃~~+50℃

Humidity

0~~90%,No condensation

Operating Altitude m

≤2000

Protection functions

Complete protection features include input reverse polarity and undervoltage protection, output overload and short-circuit protection, and over-temperature protection.

Other

It uses a power frequency isolation transformer, provides a pure sine wave output, is completely stable, and has a strong load capacity.