1  | 19 inch 2U standard chassis, user can choose desktop or rack type  | 
2  | Constant voltage and constant current function  | 
3  | Low ripple and high stability  | 
4  | Continuous adjustable output voltage and current  | 
5  | Digital adjustment of encoder to make the adjustment more precise  | 
6  | Adopting PSFB-ZVS switching mode with high conversion efficiency  | 
7  | Over-voltage, Overheat and Over-voltage Protection of Electric Power Input  | 
8  | LAN and RS485/RS422 communication interface  | 
9  | MODBUS-RTU Standard Communication Protocol  | 
10  | Monitoring by computer software  | 
11  | Parameters can be calibrated by software  | 
12  | Local and Program Controlled Dual Operation Mode  | 
13  | Output rated power 600W or 1200W  | 
14  | Various models of rated voltage 1000V~12KV and rated current 0.1A-1.2A are available.  | 
Front Panel 
  | 
  | 
①  | Power Open Switch  | |||
②  | Key Function Analysis  | FINE-Voltage and Current Rough and Fine Adjustment Selection Key;  | ||
LIMI-Voltage and Current Preset Display Key;  | ||||
OVP-SET-Over-voltage Setting Value Key;  | ||||
LOCK-Power panel lock button;  | ||||
REM-Programmable disconnection and long press address setting button;  | ||||
OUT-power output control button;  | ||||
③  | Analysis of State Indicator  | FINE -Voltage and Current Fine Selection Indicator Light for Fine Adjustment;  | ||
LIMIT -Voltage and Current Preset Display Indicator, turn on as preset value;  | ||||
OVP-SET-Over-voltage setting indicator light to display the over-voltage setting value;  | ||||
ACF-Input over-voltage indicator light, turn on input over-voltage;  | ||||
OTP-Temperature Protection Indicator Light for Internal Temperature Protection of Power Supply;  | ||||
OVP - Over-voltage Indicator, turn on the power output over-voltage;  | ||||
LOCK - Power Lock Indicator light, power is locked;  | ||||
REM - Programmable Indicator Light, which is programmed for power supply;  | ||||
OUT - Output status indicator, turn on for power supply;  | ||||
CV - constant voltage indicator lamp, power supply is in constant voltage state;  | ||||
④  | Adjustment area  | V-SET - Output Voltage Knob;  | ||
I-SET - Output Constant Current Knob.  | ||||
⑤  | Output voltage measurement terminal  | Red - output positive; black - output negative. (The power supply in this series is not connected internally and can not be used.High voltage power supply no this interface)  | ||
⑥  | Digital display  | Including voltage display area and current display area.  | ||
Back Panel  | 
  | |||
①  | RS-485/RS-422 Communication Interface  | ②  | LAN Communication Interface  | |
③  | Output Terminal  | ④  | Cooling window  | |
⑤  | AC NPUT PORT  | |||
TECHNICAL SPECIFICATIONS  | ||||
Model  | IPS-ATDP8000-0.15  | |||
 
 Rated value 
  | Voltage(Empty Load)  | 500~8000VDC  | ||
Current  | 0~0.15A  | |||
Over-voltage protection  | 0~8800V  | |||
 Setting resolution 
  | Over-Voltage  | 0.1V  | ||
Voltage  | 0.1V  | |||
Current  | 0.1mA  | |||
Display resolution 
  | Voltage  | 0.1V  | ||
Current  | 0.1mA  | |||
 Display Value Accuracy  | Voltage  | ≤0.1%+2LSB  | ||
Current  | ≤0.5%+2LSB  | |||
Load regulation rate  | Voltage  | ≤0.5%+2LSB  | ||
Current  | ≤1%+2LSB  | |||
 Power regulation rate  | Voltage  | ≤0.5%+2LSB  | ||
Current  | ≤1%+2LSB  | |||
Ripple (RMS)  | Voltage  | ≤1‰  | ||
Size(MM)  | 520L*482W*88H  | |||
ENVIRONMENTAL PARAMETERS  | ||||
1  | AC INPUT  | 220VAC (+10% 47Hz-63Hz)  | ||
2  | Heat dissipation mode  | forced heat dissipation by fan  | ||
3  | Operating ambient temperature  | 0-40 C  | ||
4  | Storage ambient temperature  | -20-70 C  | ||
5  | Maximum ambient humidity for indoor use design  | 95%  | ||