IPS- LNS-L-Custom-200K 200KVA Dispute Resolution Mechanism Customization Blockchain Technology Custom Application IoT Protocol Custom Adaptation
①Model:IPS- LNS-L-Custom-200K ②AC INPUT (Bypass): 1-phase 2-wire 220VAC±15% 50/60HZ±5Hz or Customize ③DC INPUT: 40-850VDC (customizable 850-1500VDC) ④Maximum equipment power: 400KVA ; Rated equipment power: 200KVA ⑤Application: Split-phase load scenarios (e.g., special household appliances, imported equipment) (or customized for different areas) ⑥Adjusting method: Color touchscreen, switchable between Chinese and English, integrated display and control, and clear display of operating data ⑦Split-phase output [L1-L2-N], maximum efficiency 96%, support dry contact control ⑧Protection features include input reverse connection protection, over/under voltage protection, output overload/overcurrent protection, drive protection, and overheating protection.
Datasheet: Download

Single-phase inverter power supply parameters

Model

LNS*—D—*K

Power (KVA)

5

10

20

30

50

100

150

200

DC Input

Input voltage range

40-850V

The DC voltage range can be selected according to the power requirements; other voltages are available upon request.

(850-1500V)

Bypass input

Allowable Input V Range

220Vac±15%, other voltages available upon request

Input frequency range

50/60Hz±5Hz, other frequencies available upon request

Bypass transfer time

≥200ms, customizable to <10ms

Communication Output

Rated Output V

220VAC other voltages available upon request

Rated Output Freq

50/60Hz, other frequencies available upon request

Output V Accuracy

±1%

Output Freq Accuracy

±0.1%

Rated Current (A)

22.8

45.5

91

136.4

227.3

454.6

681.9

909.1

The rated current is calculated at an output voltage of AC 220V.

THD (Waveform Distortion Rate)

<3% (linear load)

Dynamic Response Time

2ms (load 0-100%)

Overload Capacity

110% for 10 minutes, 200% for 3 seconds, customizable up to 400% for 1 second

CF (Crest Factor)

3:1

Max Inverter Efficiency

96%

WorkingEnvironment

Insulation Strength

(In/Out)

1500VAC,1 minute

Noise (at 1meter)

≤65dB(1 meter away)

Operating Ambient

Temp

-10℃ to -50℃  Other temperatures can be customized

Humidity

0-90%, non-condensing

Operating altitude (m)

≤6000m, derating required above 2000 meters (1% derating for every 100 meters increase in altitude)

Indicator lights

Bypass, Inversion (or Operation, Fault)

Display method

Touchscreen/LED digital display

Protection functions

It features multiple protection functions, including input reverse connection protection, input over/undervoltage protection, output overload/overcurrent protection, three-phase voltage imbalance protection, drive protection, and overheating protection.

Emergency shutdown

Equipped with an emergency stop button.

Protection level

IP20 (customizable to IP54)


Three-phase inverter power supply parameters

Model

LNS*—S—*K

Power (KVA)

10

30

50

100

200

500

800

1000

DC Input

Input voltage range

40-850V

The DC voltage range can be selected according to the power requirements; other voltages are available upon request.

(850-1500V)

Bypass input

Allowable Input V Range

380VAC±15%, other voltages available upon request

Input frequency range

50/60Hz±5Hz, other frequencies available upon request

Bypass transfer time

≥200ms, customizable to <10ms

Communication Output

Rated V & Freq

380VAC 50/60Hz Other voltages/frequencies are available upon request.

Output V Accuracy

±1%

Output Freq Accuracy

±0.1%

Rated Current (A)

15.2

45.6

76

152

303.9

760

1216

1520

The rated current is calculated based on an output voltage of AC380V.

THD (Waveform Distortion Rate)

<3% (linear load)

Dynamic Response Time

2ms (load 0-100%)

Overload Capacity

110% for 10 minutes, 200% for 3 seconds, customizable up to 400% for 1 second

CF (Crest Factor)

3:1

Max Inverter Efficiency

100%

WorkingEnvironment

Insulation Strength

(In/Out)

1500VAC,1 minute

Noise (at 1meter)

≤65dB(1 meter away)

Operating Ambient

Temp

-10℃ to -50℃  Other temperatures can be customized

Humidity

0-90%, non-condensing

Operating altitude (m)

≤6000m, derating required above 2000 meters (1% derating for every 100 meters increase in altitude)

Indicator lights

Bypass, Inversion (or Operation, Fault)

Display method

Touchscreen/LED digital display

Protection functions

It features multiple protection functions, including input reverse connection protection, input over/undervoltage protection, output overload/overcurrent protection, three-phase voltage imbalance protection, drive protection, and overheating protection.

Emergency shutdown

Equipped with an emergency stop button.

Protection level

IP20 (customizable to IP54)