| Model | IPS-SPT12-260 | IPS-SPT24-166 | IPS-SPT36-1111 | IPS-SPT48-83.3 | IPS-SPT100-40 | IPS-SPT200-20 | IPS-SPT400-10 | |
| Item | Technical indicators | |||||||
| Output | DC voltage | 12VDC | 24VDC | 36VDC | 48VDC | 100VDC | 200VDC | 400VDC | 
| Rated current | 0~260A | 0~166.6A | 0~111A | 0~83.3A | 0-40A | 0~20A | 0~10A | |
| Rated power | 4000W | |||||||
| Ripple and noise | <150mV | <150mV | <240mV | <240mV | <240mV | <240mV | <240mV | |
| Voltage accuracy | ±1% | |||||||
| Output voltage regulation range | 0~12VDC | 0~24VDC | 0~36VDC | 0~48VDC | 0~100VDC | 0~200VDC | 0~400VDC | |
| Load adjustment rate | 0.3% | |||||||
| Linear adjustment rate | 0.5% | |||||||
| Input | Voltage range | 180-264VAC 340-440VAC;254VDC~370VDC | ||||||
| Efficiency (typical) | >85% | |||||||
| Working current | 220VAC;21A | |||||||
| Impulse current | 60A 230VAC | |||||||
| Start, rise, hold time | 2000ms、50ms、20ms;230VAC | |||||||
| Protect | Over temperature protection | 105% ~ 135% type; Constant current output + V0 drop undervoltage point cut-off output reset; Power on again | ||||||
| Over temperature | RTH3;The fan operates normally, ≥ N90°C, and the output is closed | |||||||
| Environment | Operating temperature, humidity | -10°C~+50°C;20%-90RH | ||||||
| Storage temperature, humidity | -20°C~+85°C;10%~95RH | |||||||
| Safety regulations | Withstand voltage | Input-output: 1.5kVac input housing: 1.5kVac output housing: 05kvac for 1 minute | ||||||
| Leakage current | Input-output 1.5KVAC Time< 6mA | |||||||
| Leakage current | Input-output 220VAC Time<1.5mA | |||||||
| Isolation resistance | Input-output, input-housing, output-housing,500VDC/100MΩ | |||||||
| Other | Size | 315*208*73(MM) | ||||||
| NW/GW | 6KG/7KG | |||||||
 
         
         
         
                         
                        